Kemppi Welder Error Codes
Every welder error stops the weld cell, and in OEE it is lost availability. These are the error codes of Kemppi welders (X5 FastMig, X3 FastMig, AX MIG Welder, Master M, Minarc M and Kempact RA, plus the Master S, Master T, MasterTig and Minarc T machines that share the numbers): what each one means, the likely causes, the first checks, and how to log it so it stops coming back.
How errors show
X5 FastMig, X3 FastMig, AX MIG Welder, Master M, Master S, Master T, MasterTig and Minarc M: when an error occurs the control panel shows the error number and title. The X5 Wire Feeder 300 AP/APC panel and the Master M and Minarc M panels also show the possible cause and a proposed action; the X3 panel shows the number, and Minarc T panels show Err and the number.
X8 MIG Welder: the Control Pad shows the number and title of the error, the possible reasons and the actions to fix it, and View > Error log lists the error history. The wire feeder control panel shows the number and title. The gun remote control display shows only a symbol: system warning (blinks for 10 seconds, then stays on.
Welding still enabled), WPS warning (a key parameter is outside the WPS limits and shows in red. Welding still enabled) or system error (welding disabled). Kempact RA shows Error and a number (Error 2, 3 and 4 are listed).
MinarcMig 190 AUTO and 220 AUTO have no numbered codes: a yellow overheating light comes on when the machine hits its duty cycle limit or the supply voltage is out of range, and goes out once the machine has cooled.
For most hardware codes Kemppi's action is to restart the power source or welding system and contact Kemppi service if the error comes back; for overheating codes (4, 14, 16) do not switch the machine off, let the fans cool it.
X8: to take the cover plate off, first unplug the power source from the mains, wait about 2 minutes, then discharge the capacitor. Kempact RA: checks on the mains power must be done by an authorised trained electrician.
Sources: X5 FastMig Welding safety and maintenance topics, X8 MIG Welder periodic maintenance topic (userdoc.kemppi.com), Kempact RA manual 1922090 (PDF page 32). Follow lockout/tagout and your site's safe-work procedures, and check the manual for your exact model before you act.
Quick lookup
Errors stop the welder and the cell it serves, so in OEE they are availability losses; a warning is an early sign.
Type a code or a word (overheated, mains, gas, wire feeder) to filter the list. Click a code for its causes and first checks. One number can mean different things on different machines, so those codes have one row per machine family, named in brackets.
69 codes
| Code | Name |
|---|---|
| 1 | Power source not calibrated |
| 2 | Too low mains voltage |
| 3 | Too high mains voltage |
| 4 | Power source is overheated (X3, X5, AX, Master, Minarc) |
| 4 | Wire feed motor over current (Kempact RA) |
| 5 | Internal 24V voltage is too low |
| 7 | Wire feeder not found |
| 8 | Initialization error in FPGA card |
| 9 | Measurement cable failure |
| 10 | Unsupported welding process |
| 11 | FET unit failure |
| 12 | Welding cable failure |
| 13 | IGBT overcurrent |
| 14 | IGBT overheated |
| 16 | Main transformer is overheated |
| 17 | Phase is missing from mains supply |
| 20 | Power source cooling failure |
| 24 | Cooling liquid overheated |
| 26 | Cooling liquid not circulating |
| 27 | Cooler not found |
| 33 | Welding cable calibration failure |
| 34 | Unknown welding load |
| 35 | Too high mains current |
| 36 | DC-link undervoltage |
| 37 | DC-link overvoltage |
| 38 | Mains voltage too high or too low |
| 40 | VRD error |
| 41 | Wire feeder not calibrated |
| 42 | High current in wire feeder motor |
| 43 | Overcurrent in wire feeder motor |
| 44 | Wire speed measurement is missing |
| 45 | Low gas pressure |
| 50 | License error (X5, Master M) |
| 50 | Welding program error (AX MIG Welder) |
| 51 | Rear drive roll slipping |
| 53 | Collision detected |
| 56 | Wire feeder hardware fault |
| 57 | Low shielding gas flow |
| 58 | Assistive wire feeder was disconnected |
| 59 | Gas sensor unit missing |
| 60 | Welding torch speed signal missing |
| 61 | Operation not allowed |
| 62 | Power source not found |
| 64 | Robot control device lost |
| 65 | Subfeeder not allowed |
| 80 | Torch cooling required |
| 81 | Welding program data missing |
| 103 | Empty memory channel |
| 129 | Filler wire stuck |
| 130 | RCM hardware fault |
| 131 | Fieldbus initialization failed |
| 132 | Robot not responding |
| 133 | Stop switch pressed |
| 134 | Gate door open |
| 141 | High current in welding torch motor |
| 142 | Overcurrent in welding torch motor |
| 161 | High current in assistive wire feeder motor |
| 162 | Overcurrent in assistive wire feeder motor |
| 163 | Wire speed measurement from assistive wire feeder is missing |
| 164 | Main wire feeder is not supported by the assistive wire feeder |
| 165 | Assistive wire feeder hardware fault |
| 166 | Assistive wire feeder feed rolls slipping |
| 171 | Gas sensor unit not calibrated |
| 238 | Power source serial number is missing |
| 244 | Internal memory failure |
| 245 | Demo time left: %min min |
| 246 | Demo time has expired |
| 250 | Internal memory failure |
| 255 | Unsupported hardware |
Each code: causes and first checks
Error 1: Power source not calibrated
Hits OEE: AvailabilityWhat it means: The power source has lost its calibration data.[1][2][3][4][5][6][7][8][9][10][11][12][13][14]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Minarc M 223, 223P; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC; Minarc T 223 DC. Master 315 adds that the equipment operation is limited while this error is active.
Machine response: Kemppi's action: restart the power source; if the error stays, contact Kemppi service.
Likely causes
- Power source calibration lost
First checks, in this order
- Restart the power source.
- If the error comes back, contact Kemppi service.
Error 2: Too low mains voltage
Hits OEE: AvailabilityWhat it means: The mains supply voltage is too low for the power source.[1][2][3][4][5][6][7][8][9][10][11][12][14][19]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Minarc M 223, 223P; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 DC; Kempact RA. Kempact RA prints it as Error 2: Mains under voltage (under voltage that disturbs welding).
Machine response: Kemppi's action: restart the power source; if the error stays, contact Kemppi service.
Likely causes
- Mains network voltage too low
First checks, in this order
- Restart the power source.
- Check the quality and voltage of the mains supply (the Kempact RA manual adds this check).
- If it persists, contact Kemppi service.
Error 3: Too high mains voltage
Hits OEE: AvailabilityWhat it means: The mains supply voltage is too high. On the Kempact RA this covers momentary spikes or continuous overvoltage that could damage the machine.[1][2][3][4][5][6][7][8][9][10][11][12][13][14][19]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Minarc M 223, 223P; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC; Minarc T 223 DC; Kempact RA. Kempact RA prints it as Error 3: Mains over voltage.
Machine response: Kemppi's action: restart the power source; if the error stays, contact Kemppi service.
Likely causes
- Mains network voltage too high
- Voltage spikes on the supply
First checks, in this order
- Restart the power source.
- Check the quality and voltage of the mains supply.
- If it persists, contact Kemppi service.
Error 4: Power source is overheated (X3, X5, AX, Master, Minarc)
Hits OEE: AvailabilityWhat it means: The power source got too hot, typically after a long welding session at high power.[1][2][3][4][5][6][7][8][9][10][11][12][13][14]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Minarc M 223, 223P; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC; Minarc T 223 DC. On the Kempact RA, Error 4 means Wire feed motor over current (separate row).
Machine response: Kemppi's action: do not switch the machine off; let the fans cool it. If the fans are not running, contact Kemppi service.
Likely causes
- Long welding session at high power
First checks, in this order
- Leave the machine switched on so the fans can cool it.
- Check that the fans are running; if they are not, contact Kemppi service.
Error 4: Wire feed motor over current (Kempact RA)
Hits OEE: AvailabilityWhat it means: The wire feed motor current is above its design limit.[19]
Also on: Machines: Kempact RA. Kempact RA 251R, 251A, 253R, 253A, 323R, 323A and MV versions. On the other models, code 4 is Power source is overheated.
Machine response: Kemppi's action: check the contact tip, liner and wire feed mechanism.
Likely causes
- Worn or blocked contact tip
- Dirty or worn liner
- Wire feed mechanism problem
First checks, in this order
- Check the welding gun contact tip.
- Check the liner.
- Check the wire feed mechanism.
Error 5: Internal 24V voltage is too low
Hits OEE: AvailabilityWhat it means: An internal 24 V power supply unit in the power source is not working.[1][2][3][4][5][6][7][13][14]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Minarc M 223, 223P; Minarc T 223 ACDC; Minarc T 223 DC.
Machine response: Kemppi's action: restart the power source; if the error stays, contact Kemppi service.
Likely causes
- Inoperative 24 V power supply unit in the power source
First checks, in this order
- Restart the power source.
- If it persists, contact Kemppi service.
Error 7: Wire feeder not found
Hits OEE: AvailabilityWhat it means: The power source cannot find the wire feeder: it is not connected or the connection is faulty.[1][2][3]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder.
Machine response: Kemppi's action: check the control cable and its connectors.
Likely causes
- Wire feeder not connected to the power source
- Faulty control cable or connector
First checks, in this order
- Check the control (interconnection) cable and its connectors.
Error 8: Initialization error in FPGA card
Hits OEE: AvailabilityWhat it means: The control card in the power source is faulty or its software failed.[1][3]
Also on: Machines: X5 FastMig; AX MIG Welder.
Machine response: Kemppi's action: restart the power source; if the error stays, contact Kemppi service.
Likely causes
- Faulty control card
- Software failure in the power source
First checks, in this order
- Restart the power source.
- If it persists, contact Kemppi service.
Error 9: Measurement cable failure
Hits OEE: AvailabilityWhat it means: The voltage sensing cable is not connected to the workpiece, or the measurement cable connection is faulty.[1][3]
Also on: Machines: X5 FastMig; AX MIG Welder.
Machine response: Kemppi's action: connect the voltage sensing cable and check the cable and connectors.
Likely causes
- Voltage sensing cable not connected to the workpiece
- Faulty measurement cable or connector
First checks, in this order
- Connect the voltage sensing cable to the workpiece.
- Check the measurement cable and its connectors.
Error 10: Unsupported welding process
Hits OEE: AvailabilityWhat it means: A memory channel holds a welding process that the machine does not support.[4][5][6]
Also on: Machines: Master M 358; Master M 353, 355; Master M 205, 323.
Machine response: Kemppi's action: check the memory channel definitions.
Likely causes
- Unsupported welding process stored in a memory channel
First checks, in this order
- Check that all memory channel definitions use supported processes.
Error 11: FET unit failure
Hits OEE: AvailabilityWhat it means: A FET unit in the power source is not working.[1][3]
Also on: Machines: X5 FastMig; AX MIG Welder.
Machine response: Kemppi's action: restart the power source; if the error stays, contact Kemppi service.
Likely causes
- Inoperative FET unit in the power source
First checks, in this order
- Restart the power source.
- If it persists, contact Kemppi service.
Error 12: Welding cable failure
Hits OEE: AvailabilityWhat it means: The plus and minus welding cables are connected together (short circuit between the welding and earth return circuits).[1][2][3][4][5][6][7][13][14]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Minarc M 223, 223P; Minarc T 223 ACDC; Minarc T 223 DC.
Machine response: Kemppi's action: check the welding cable and earth return cable connections.
Likely causes
- Welding cable and earth return cable touching or shorted
First checks, in this order
- Check the connections of the welding cable and the earth return cable.
Error 13: IGBT overcurrent
Hits OEE: AvailabilityWhat it means: Overcurrent in the IGBT power stage; Kemppi gives an inoperative mains transformer in the power source as the cause.[1][2][3][4][5][6]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323.
Machine response: Kemppi's action: restart the power source; if the error stays, contact Kemppi service.
Likely causes
- Inoperative mains transformer in the power source
First checks, in this order
- Restart the power source.
- If it persists, contact Kemppi service.
Error 14: IGBT overheated
Hits OEE: AvailabilityWhat it means: The IGBT power stage overheated after a long session at high power or in a hot environment.[1][2][3][4][5][6][7][13][14]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Minarc M 223, 223P; Minarc T 223 ACDC; Minarc T 223 DC.
Machine response: Kemppi's action: do not switch the machine off; let the fans cool it. If the fans are not running, contact Kemppi service.
Likely causes
- Long welding session at high power
- High ambient temperature
First checks, in this order
- Leave the machine switched on so the fans can cool it.
- Check that the fans are running; if not, contact Kemppi service.
Error 16: Main transformer is overheated
Hits OEE: AvailabilityWhat it means: The main transformer overheated after a long session at high power or in a hot environment.[4][5][6]
Also on: Machines: Master M 358; Master M 353, 355; Master M 205, 323.
Machine response: Kemppi's action: do not switch the machine off; let the fans cool it. If the fans are not running, contact Kemppi service.
Likely causes
- Long welding session at high power
- High ambient temperature
First checks, in this order
- Leave the machine switched on so the fans can cool it.
- Check that the fans are running; if not, contact Kemppi service.
Error 17: Phase is missing from mains supply
Hits OEE: AvailabilityWhat it means: The mains supply has lost one or more of its phases.[1][2][3][4][5][6][8][9][10][11][12]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC.
Machine response: Kemppi's action: check the mains cable, connectors and supply voltage.
Likely causes
- Phase missing from the mains supply
- Damaged mains cable or connector
First checks, in this order
- Check the mains cable and its connectors.
- Check the voltage of the mains supply on all phases.
Error 20: Power source cooling failure
Hits OEE: AvailabilityWhat it means: The cooling capacity of the power source has dropped.[1][2][3][4][5][6][10][11][12][13][14]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC; Minarc T 223 DC.
Machine response: Kemppi's action: clean the filters and cooling channel and check the fans.
Likely causes
- Dirty filters or cooling channel
- Cooling fans not running
First checks, in this order
- Remove dirt from the cooling channel and clean the filters.
- Check that the cooling fans run; if they do not, contact Kemppi service.
Error 24: Cooling liquid overheated
Hits OEE: AvailabilityWhat it means: The coolant in the cooling unit overheated after a long session at high power or in a hot environment.[1][2][3][4][5][6][10][11][12][13]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC.
Machine response: Kemppi's action: keep the cooler running until the liquid cools; contact Kemppi service if the fans are not running.
Likely causes
- Long welding session at high power
- High ambient temperature
First checks, in this order
- Leave the cooler switched on so the liquid keeps circulating while the fans bring its temperature down.
- If the fans are not running, contact Kemppi service.
Error 26: Cooling liquid not circulating
Hits OEE: AvailabilityWhat it means: The coolant is not circulating: there is no liquid, or the circulation is blocked.[1][2][3][4][5][6][10][11][12][13]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC.
Machine response: Kemppi's action: check the coolant level, hoses and connectors.
Likely causes
- Coolant level too low or empty
- Blocked hose or connector
First checks, in this order
- Check the liquid level in the cooler.
- Check the hoses and connectors for blockage.
Error 27: Cooler not found
Hits OEE: AvailabilityWhat it means: Cooling is switched on in the settings menu, but no cooler is connected to the power source or its cabling is faulty.[1][2][3][4][5][6][10][11][12][13][20]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC; FastMig with MXF 63, 65, 67 wire feeder. The MXF 63, 65, 67 wire feeder manual (FastMig) shows Err 27 on a FastMig Pulse when water cooling is left on AUTO with no cooling unit and an air cooled gun; set Water Cooling to OFF in the System Config Menu.
Machine response: Kemppi's action: check the cooler connections, or turn cooling off in the settings if no cooler is used.
Likely causes
- Cooling turned on in settings without a cooler connected
- Faulty cooler cabling
First checks, in this order
- Check the cooler connections.
- If no cooler is used, turn cooling off in the settings menu.
Error 33: Welding cable calibration failure
Hits OEE: AvailabilityWhat it means: The welding cable calibration did not succeed.[1][2][3][4][5][6]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323.
Machine response: Kemppi's action: check the welding system cables and connections.
Likely causes
- Welding system cable or connection problem during calibration
First checks, in this order
- Check the welding system cables and their connections, then repeat the calibration.
Error 34: Unknown welding load
Hits OEE: AvailabilityWhat it means: An unknown load is connected to the DIX welding connectors.[8][9][10][11][12]
Also on: Machines: Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC.
Machine response: Kemppi's action: remove the unintended load and restart the power source.
Likely causes
- Unintended resistive load connected to the welding equipment
First checks, in this order
- Remove any unintended resistive load from the welding equipment.
- Restart the power source.
Error 35: Too high mains current
Hits OEE: AvailabilityWhat it means: The current drawn from the mains is too high.[4][5][6][8][9][10][11][12]
Also on: Machines: Master M 358; Master M 353, 355; Master M 205, 323; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC.
Machine response: Kemppi's action: reduce the welding power.
Likely causes
- Welding power too high for the supply
First checks, in this order
- Reduce the welding power.
Error 36: DC-link undervoltage
Hits OEE: AvailabilityWhat it means: The internal DC link voltage of the power source is too low.[8][9][10][11][12]
Also on: Machines: Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC.
Machine response: Kemppi's action: check the mains voltage and/or the supply cable.
Likely causes
- Low mains voltage
- Supply cable problem
First checks, in this order
- Check the mains voltage.
- Check the supply cable.
Error 37: DC-link overvoltage
Hits OEE: AvailabilityWhat it means: The internal DC link voltage of the power source is too high.[8][9][10][11][12]
Also on: Machines: Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC.
Machine response: Kemppi's action: check the mains voltage.
Likely causes
- High mains voltage
First checks, in this order
- Check the mains voltage.
Error 38: Mains voltage too high or too low
Hits OEE: AvailabilityWhat it means: The mains voltage is outside the allowed range, too high or too low.[8][9][10][11][12]
Also on: Machines: Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC.
Machine response: Kemppi's action: check the mains voltage and/or the supply cable.
Likely causes
- Mains voltage out of range
- Supply cable problem
First checks, in this order
- Check the mains voltage.
- Check the supply cable.
Error 40: VRD error
Hits OEE: AvailabilityWhat it means: The open circuit voltage is above the VRD (voltage reduction device) limit.[1][2][3][4][5][6][8][9][10][11][12][13][14]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC; Minarc T 223 DC.
Machine response: Kemppi's action: restart the power source; if the error stays, contact Kemppi service.
Likely causes
- Open circuit voltage above the VRD limit
First checks, in this order
- Restart the power source.
- If it persists, contact Kemppi service.
Error 41: Wire feeder not calibrated
Hits OEE: AvailabilityWhat it means: The wire feeder has lost its calibration.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Wire feeder calibration lost
First checks, in this order
- Restart the welding system.
- If it persists, contact Kemppi service.
Error 42: High current in wire feeder motor
Hits OEE: AvailabilityWhat it means: The wire feeder motor current is high, usually from too much feed roll pressure or dirt in the wire line.[1][3][4][5][6]
Also on: Machines: X5 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323. Code 43 is the stronger overcurrent version of the same problem.
Machine response: Kemppi's action: adjust the feed roll pressure, clean the wire line and change worn gun parts.
Likely causes
- Feed roll pressure too high
- Dirt in the wire line
- Worn parts in the welding gun
First checks, in this order
- Adjust the feed roll pressure.
- Clean the wire line.
- Change worn parts in the welding gun.
Error 43: Overcurrent in wire feeder motor
Hits OEE: AvailabilityWhat it means: The wire feeder motor is in overcurrent, usually from too much feed roll pressure or dirt in the wire line.[1][2][3][4][5][6][7]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Minarc M 223, 223P. On the Kempact RA the same problem is Error 4 (Wire feed motor over current).
Machine response: Kemppi's action: adjust the feed roll pressure, clean the wire line and change worn gun parts.
Likely causes
- Feed roll pressure too high
- Dirt in the wire line
- Worn parts in the welding gun
First checks, in this order
- Adjust the feed roll pressure.
- Clean the wire line.
- Change worn parts in the welding gun.
Error 44: Wire speed measurement is missing
Hits OEE: AvailabilityWhat it means: The wire feeder has no wire speed signal, from a faulty sensor or wiring in the wire feeder.[1][2][3][4][5][6]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Faulty wire speed sensor
- Faulty wiring in the wire feeder
First checks, in this order
- Restart the welding system.
- If it persists, contact Kemppi service.
Error 45: Low gas pressure
Hits OEE: AvailabilityWhat it means: The shielding gas pressure is too low.[4][5][6]
Also on: Machines: Master M 358; Master M 353, 355; Master M 205, 323.
Machine response: Kemppi's action: check and adjust the shielding gas flow.
Likely causes
- Shielding gas pressure too low, for example an empty cylinder
First checks, in this order
- Check and adjust the shielding gas flow.
Error 50: License error (X5, Master M)
Hits OEE: AvailabilityWhat it means: The license for the selected feature is missing.[1][4][5]
Also on: Machines: X5 FastMig; Master M 358; Master M 353, 355. On the AX MIG Welder, code 50 means Welding program error (separate row).
Machine response: Kemppi's action: install the license.
Likely causes
- Feature used without its license
First checks, in this order
- Install the license to keep using the feature.
Error 50: Welding program error (AX MIG Welder)
Hits OEE: AvailabilityWhat it means: The required welding program is not installed.[3]
Also on: Machines: AX MIG Welder. On the X5 FastMig and Master M, code 50 means License error.
Machine response: Kemppi's action: contact Kemppi service to install the welding programs.
Likely causes
- Welding program not installed
First checks, in this order
- Contact Kemppi service to install the welding programs.
Error 51: Rear drive roll slipping
Hits OEE: AvailabilityWhat it means: The rear drive roll of the wire feeder is slipping.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: adjust the feed roll pressure and clean the wire lines.
Likely causes
- Feed roll pressure too low
- Dirty wire lines
First checks, in this order
- Adjust the feed roll pressure.
- Clean the wire lines.
Error 53: Collision detected
Hits OEE: AvailabilityWhat it means: The welding torch has collided with an object.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: move the torch clear and check it for damage.
Likely causes
- Torch hit the workpiece, fixture or another object
First checks, in this order
- Move the welding torch away from the collision.
- Check the torch for damage.
Error 56: Wire feeder hardware fault
Hits OEE: AvailabilityWhat it means: There is an internal hardware fault in the wire feeder.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Internal wire feeder hardware fault
- Wire feeder connection problem
First checks, in this order
- Check the wire feeder connections.
- Restart the welding system; if it persists, contact Kemppi service.
Error 57: Low shielding gas flow
Hits OEE: AvailabilityWhat it means: Shielding gas flow is missing or under the warning level.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: check and adjust the shielding gas flow.
Likely causes
- Shielding gas flow too low or gas missing
First checks, in this order
- Check and adjust the shielding gas flow.
Error 58: Assistive wire feeder was disconnected
Hits OEE: AvailabilityWhat it means: The connection to the assistive wire feeder was lost during operation.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: check the assistive wire feeder connection.
Likely causes
- Assistive wire feeder connection lost
First checks, in this order
- Check the connection of the assistive wire feeder and make sure it works.
Error 59: Gas sensor unit missing
Hits OEE: AvailabilityWhat it means: The gas sensor unit in the wire feeder is faulty or its wiring is; gas sensor functions are not available.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Faulty gas sensor unit
- Faulty wiring in the wire feeder
First checks, in this order
- Check the external cable connections of the wire feeder.
- Restart the welding system; if it persists, contact Kemppi service.
Error 60: Welding torch speed signal missing
Hits OEE: AvailabilityWhat it means: The push-pull welding torch speed signal is missing.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: check the push-pull torch control cables and connector.
Likely causes
- Push-pull torch control cable disconnected
- Faulty wiring or sensor
First checks, in this order
- Check the push-pull welding torch control cables.
- Check the push-pull torch control cable connector on the wire feeder.
Error 61: Operation not allowed
Hits OEE: AvailabilityWhat it means: A subfeeder is connected, but the system settings do not have it selected.[1][3][4][5]
Also on: Machines: X5 FastMig; AX MIG Welder; Master M 358; Master M 353, 355. Master M manuals print it as Operation is not allowed.
Machine response: Kemppi's action: select the subfeeder model and type in the system settings.
Likely causes
- Subfeeder connected but not set up in the system settings
First checks, in this order
- In the control panel's system settings menu, pick the model and type of the subfeeder you use.
Error 62: Power source not found
Hits OEE: AvailabilityWhat it means: The wire feeder cannot find a power source: none is connected or the connection is faulty.[1][2][3]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder.
Machine response: Kemppi's action: check the control cable and its connectors.
Likely causes
- No power source connected to the wire feeder
- Faulty control cable or connector
First checks, in this order
- Check the control cable and its connectors.
Error 64: Robot control device lost
Hits OEE: AvailabilityWhat it means: The wire feeder lost its connection to the robot control device.[1][3][4][5]
Also on: Machines: X5 FastMig; AX MIG Welder; Master M 358; Master M 353, 355.
Machine response: Kemppi's action: check the robot control device and cables; contact Kemppi service if it persists.
Likely causes
- Robot control device or interconnection cable problem
First checks, in this order
- Check the robot control device and the interconnection cables.
- If it persists, contact Kemppi service.
Error 65: Subfeeder not allowed
Hits OEE: AvailabilityWhat it means: A subfeeder cannot be used with the selected welding process.[1][3][4][5][6]
Also on: Machines: X5 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323.
Machine response: Kemppi's action: remove the subfeeder or change the welding process.
Likely causes
- Subfeeder connected with a process that does not allow it
First checks, in this order
- Remove the subfeeder or change the welding process.
Error 80: Torch cooling required
Hits OEE: AvailabilityWhat it means: A water cooled torch is attached while the cooler is switched off.[10][11][12][13]
Also on: Machines: Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC.
Machine response: Kemppi's action: turn the cooler on or use an air cooled torch.
Likely causes
- Water cooled torch used with the cooler switched off
First checks, in this order
- Turn the cooler on in the settings menu.
- Or change to an air cooled torch.
Error 81: Welding program data missing
Hits OEE: AvailabilityWhat it means: The welding program data has been lost.[1][2][3][7][8][9][10][11][12][13][14]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Minarc M 223, 223P; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC; Minarc T 223 ACDC; Minarc T 223 DC.
Machine response: Kemppi's action: restart the power source; if the error stays, contact Kemppi service.
Likely causes
- Welding program data lost
First checks, in this order
- Restart the power source.
- If it persists, contact Kemppi service.
Error 103: Empty memory channel
Hits OEE: AvailabilityWhat it means: The robot tried to start welding with a memory channel that does not exist.[1][3][4][5]
Also on: Machines: X5 FastMig; AX MIG Welder; Master M 358; Master M 353, 355.
Machine response: Kemppi's action: check the memory channel selected by the robot.
Likely causes
- Robot selected a nonexistent memory channel
First checks, in this order
- Check the memory channel selected by the robot.
Error 129: Filler wire stuck
Hits OEE: AvailabilityWhat it means: The filler wire is stuck to the weld.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: make sure welding has stopped and cut the wire.
Likely causes
- Filler wire stuck to the weld
First checks, in this order
- Make sure welding has stopped, then cut the filler wire.
- Take care around hot surfaces.
Error 130: RCM hardware fault
Hits OEE: AvailabilityWhat it means: There is an internal hardware failure in the RCM.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: check external I/O and add-on cards; contact Kemppi service if it persists.
Likely causes
- Internal RCM hardware failure
- External I/O, add-on card or add-on card power supply problem
First checks, in this order
- Check external I/O connections, optional add-on cards and their power supplies.
- If it persists, contact Kemppi service.
Error 131: Fieldbus initialization failed
Hits OEE: AvailabilityWhat it means: The RCM could not initialize the fieldbus module; the module is unsupported or faulty.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: remove the fieldbus module and check that it is supported.
Likely causes
- Unsupported fieldbus module
- Faulty fieldbus module
First checks, in this order
- Remove the fieldbus module and check that the RCM supports it.
Error 132: Robot not responding
Hits OEE: AvailabilityWhat it means: There is a communication problem between the robot and the RCM.[1][3][4][5]
Also on: Machines: X5 FastMig; AX MIG Welder; Master M 358; Master M 353, 355.
Machine response: Kemppi's action: check the fieldbus cabling, connectors and module.
Likely causes
- Fieldbus cabling, connector or fieldbus module problem
First checks, in this order
- Check the fieldbus cabling and connectors.
- Check the fieldbus module.
Error 133: Stop switch pressed
Hits OEE: AvailabilityWhat it means: The welding system stopped because the stop switch is pressed.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: release the stop switch.
Likely causes
- Stop switch pressed
First checks, in this order
- Release the stop switch.
Error 134: Gate door open
Hits OEE: AvailabilityWhat it means: The gate door has been opened.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: close the gate door.
Likely causes
- Gate door open
First checks, in this order
- Close the gate door.
Error 141: High current in welding torch motor
Hits OEE: AvailabilityWhat it means: The motor in the push-pull welding torch draws high current, which may degrade welding performance.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: adjust the torch feed roll pressure, clean the wire line and change worn parts.
Likely causes
- Feed roll pressure too high in the torch
- Dirt in the wire line
- Worn torch parts
First checks, in this order
- Adjust the feed roll pressure in the welding torch.
- Clean the wire line.
- Change worn parts in the welding torch.
Error 142: Overcurrent in welding torch motor
Hits OEE: AvailabilityWhat it means: The motor in the push-pull welding torch is in overcurrent.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: adjust the torch feed roll pressure, clean the wire line and check the control cables.
Likely causes
- Feed roll pressure too high in the torch
- Dirt in the wire line
- Damaged push-pull torch control cable
First checks, in this order
- Adjust the feed roll pressure in the welding torch.
- Clean the wire line and change worn parts.
- Check the torch control cables and the push-pull control cable connector on the wire feeder.
Error 161: High current in assistive wire feeder motor
Hits OEE: AvailabilityWhat it means: The assistive wire feeder motor draws high current.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: adjust the feed roll pressure, clean the wire line and change worn parts.
Likely causes
- Feed roll pressure too high
- Dirt in the wire line
- Worn torch parts
First checks, in this order
- Adjust the feed roll pressure.
- Clean the wire line.
- Change worn parts in the welding torch.
Error 162: Overcurrent in assistive wire feeder motor
Hits OEE: AvailabilityWhat it means: The assistive wire feeder motor is in overcurrent.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: adjust the feed roll pressure, clean the wire line and change worn parts.
Likely causes
- Feed roll pressure too high
- Dirt in the wire line
- Worn torch parts
First checks, in this order
- Adjust the feed roll pressure.
- Clean the wire line.
- Change worn parts in the welding torch.
Error 163: Wire speed measurement from assistive wire feeder is missing
Hits OEE: AvailabilityWhat it means: The wire speed signal from the assistive wire feeder is missing.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Faulty sensor or wiring in the wire feeder
- Mechanical obstacle in the wire feed mechanism
First checks, in this order
- Restart the welding system.
- Check the wire feed mechanism.
- If it persists, contact Kemppi service.
Error 164: Main wire feeder is not supported by the assistive wire feeder
Hits OEE: AvailabilityWhat it means: The assistive wire feeder does not support the main wire feeder model.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: check supported models and update the assistive wire feeder firmware.
Likely causes
- Unsupported main wire feeder model
- Old firmware in the assistive wire feeder
First checks, in this order
- Check the user manual for supported wire feeder models.
- Check that the assistive wire feeder has the latest firmware.
Error 165: Assistive wire feeder hardware fault
Hits OEE: AvailabilityWhat it means: The assistive wire feeder reports an internal hardware fault.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Internal hardware fault in the assistive wire feeder
- Connection problem
First checks, in this order
- Check the assistive wire feeder connections.
- Restart the welding system; if it persists, contact Kemppi service.
Error 166: Assistive wire feeder feed rolls slipping
Hits OEE: AvailabilityWhat it means: The feed rolls of the assistive wire feeder are slipping, or it ran out of wire.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: adjust the feed roll pressure, clean the wire lines and check the wire source.
Likely causes
- Feed roll pressure too low
- Dirty wire lines
- Wire source empty
First checks, in this order
- Adjust the feed roll pressure.
- Clean the wire lines.
- Check the wire source.
Error 171: Gas sensor unit not calibrated
Hits OEE: AvailabilityWhat it means: The gas sensor unit is not calibrated, or its calibration data cannot be loaded.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Gas sensor unit not calibrated
- Calibration data cannot be loaded
First checks, in this order
- Restart the welding system.
- If it persists, contact Kemppi service.
Error 238: Power source serial number is missing
Hits OEE: AvailabilityWhat it means: Communication with the serial number card in the power source failed.[1][3]
Also on: Machines: X5 FastMig; AX MIG Welder.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Serial number card communication failure
First checks, in this order
- Restart the welding system.
- If it persists, contact Kemppi service.
Error 244: Internal memory failure
Hits OEE: AvailabilityWhat it means: Internal memory initialization failed; the panel adds which unit and device it is (shown in the manual as %sub:%device).[1][2][3][4][5][6][8][9][10][11][12]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC. Code 250 has the same title but means a memory communication failure.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Internal memory initialization failure
First checks, in this order
- Restart the welding system.
- If it persists, contact Kemppi service.
Error 245: Demo time left: %min min
Warning: act before it becomes a stopWhat it means: Optional features are running on demo time; the panel shows the minutes left. When it runs out, features without a license stop working.[1][4][5]
Also on: Machines: X5 FastMig; Master M 358; Master M 353, 355.
Machine response: Kemppi's action: buy licenses to keep using the optional features.
Likely causes
- Optional features used in demo mode without a license
First checks, in this order
- Buy and install licenses for the optional features you want to keep.
Error 246: Demo time has expired
Hits OEE: AvailabilityWhat it means: The demo time has run out, so features without a license can no longer be used.[1][4][5]
Also on: Machines: X5 FastMig; Master M 358; Master M 353, 355.
Machine response: Kemppi's action: buy licenses to keep using the optional features.
Likely causes
- Demo period for optional features ended
First checks, in this order
- Buy and install licenses for the optional features.
Error 250: Internal memory failure
Hits OEE: AvailabilityWhat it means: Communication with the internal memory failed; the panel adds which unit and device it is (shown in the manual as %sub:%device).[1][2][3][4][5][6][8][9][10][11][12]
Also on: Machines: X5 FastMig; X3 FastMig; AX MIG Welder; Master M 358; Master M 353, 355; Master M 205, 323; Master S 305; Master 315; Master T 245, 355, 405; Master T 505 ACDC; MasterTig 235ACDC, 325DC, 335ACDC, 425DC. Code 244 has the same title but means a memory initialization failure.
Machine response: Kemppi's action: restart the welding system; if the error stays, contact Kemppi service.
Likely causes
- Internal memory communication failure
First checks, in this order
- Restart the welding system.
- If it persists, contact Kemppi service.
Error 255: Unsupported hardware
Hits OEE: AvailabilityWhat it means: The RCM hardware is not supported by the current firmware.[3]
Also on: Machines: AX MIG Welder.
Machine response: Kemppi's action: update the RCM firmware.
Likely causes
- RCM firmware too old for the hardware
First checks, in this order
- Update the RCM firmware.
Log it, or the same alarm comes back
An error stops the welder, and the cell waits until it is cleared, so in OEE terms it is a breakdown. Log the code, the machine and the minutes lost, every time, even when a restart clears it in seconds.
- Reason code: the code plus the cell, for example Kemppi X5 error 4, cell 2, so an overheating that comes back every shift shows up as a pattern.
- Loss bucket: a stop that needs a reset, a part or a technician is an availability loss (breakdown). Stops shorter than your micro-stop threshold go to performance (minor stops). The six big losses page shows where each one belongs.
- What to count: how often each code fires per week and the minutes it costs. Two numbers a week turn "that alarm comes up sometimes" into a ranked list. The MTBF and MTTR calculator and the downtime cost calculator do the math.
The free OEE tracker logs each stop with its reason and turns the week into a downtime Pareto, so the code that costs the most rises to the top.
fabrico.io has a MIG welder troubleshooting guide. An error code tells you what the power source detected, not what happened in the cell in the seconds before. Fabrico's camera-based OEE software syncs camera video with machine data, so you can replay the moment the cell stopped next to the code.
Frequently asked questions
Where can I find the Kemppi error codes PDF?
Each Kemppi manual has an Error codes topic on userdoc.kemppi.com, and kemppi.com/en/userdoc links the HTML manual and a PDF download for each product. The X5 FastMig, Master M 353, 355 and 358 and AX MIG Welder topics list the code, title, possible cause and proposed action; the Kempact RA PDF lists its codes in section 8. This page gathers those tables in one list.
What is Kemppi error code 171?
In Kemppi's AX MIG Welder table, error 171 is Gas sensor unit not calibrated: the gas sensor unit is not calibrated or its calibration data cannot be loaded. Restart the welding system, and contact Kemppi service if the error comes back. For another machine, look the number up in that machine's own manual; an X8 MIG Welder shows the title and actions on its Control Pad.
What is Kemppi error code 54?
This page has no row for code 54, because the Kemppi tables collected here (X3, X5, AX MIG Welder, Master M, Master S, Master T, MasterTig, Minarc and Kempact RA) do not list it. On the AX MIG Welder the neighbouring codes are 53 Collision detected and 56 Wire feeder hardware fault. Read the full text on the machine (the X5 300 AP/APC panel, Master M panels and the X8 Control Pad show the title, cause and action), note the number and contact Kemppi service if it stays.
What does Kemppi error 4 mean?
On X3 and X5 FastMig, AX MIG Welder, Master M, Master S, Master T, MasterTig and Minarc machines, error 4 is Power source is overheated, usually after a long session at high power: do not switch the machine off, let the fans cool it, and call Kemppi service if the fans are not running. On a Kempact RA, Error 4 is Wire feed motor over current: check the contact tip, liner and wire feed mechanism.
How do I see the error code on a Kemppi X8 MIG Welder?
The X8 Control Pad shows the error number and title with the possible reasons and the actions to fix it, and View > Error log shows past errors. The wire feeder control panel shows the number and title. The gun remote display shows only a symbol: system warning and WPS warning still allow welding, a system error disables it, so check the Control Pad or wire feeder panel for the details.
What do Kemppi errors 2, 3 and 17 mean?
They are mains supply errors. Error 2 is Too low mains voltage and error 3 Too high mains voltage (on the Kempact RA: Mains under voltage and Mains over voltage); restart the power source, check the supply quality and call Kemppi service if it stays. Error 17 is Phase is missing from mains supply: check the mains cable and connectors and measure the voltage on every phase.
Sources
Codes and meanings follow the manufacturer documentation below. Wording is ours, simplified for the shop floor; the manual for your exact model and software version wins if it differs.
- X5 FastMig Manual 1920960, rev. 2612, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- X3 FastMig Manual 1922370, rev. 2641, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- AX MIG Welder Manual 1921900, rev. 2643, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Master M 358 Manual 1921980, rev. 2635, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Master M 353, 355 Manual 1921960, rev. 2635, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Master M 205, 323 Manual 1922130, rev. 2608, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Minarc M 223, 223P Manual 1922890, rev. 2627, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Master S 305 Manual 1922760, rev. 2525, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Master 315 Manual 1921530, rev. 2244, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Master T 245, 355, 405 Manual 1922740, rev. 2643, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Master T 505 ACDC Manual 1922750, rev. 2634, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- MasterTig 235ACDC, 325DC, 335ACDC, 425DC Manual 1920900, rev. 2540, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Minarc T 223 ACDC Manual 1922350, rev. 2547, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Minarc T 223 DC Manual 1922590, rev. 2547, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- X8 MIG Welder Manual 1902370, rev. 2324, Error codes topic, Kemppi Oy, hosted on userdoc.kemppi.com
- X8 MIG Welder Manual 1902370, rev. 2324, Periodic maintenance of power source and wire feeder topic, Kemppi Oy, hosted on userdoc.kemppi.com
- X5 FastMig Manual 1920960, rev. 2612, Daily, periodic and annual maintenance topic, Kemppi Oy, hosted on userdoc.kemppi.com
- X5 FastMig Manual 1920960, rev. 2612, Welding safety topic, Kemppi Oy, hosted on userdoc.kemppi.com
- Kempact 251R, 251A, 253R, 253A, 323A, 323R, 253RMV, 253AMV, 323RMV, 323AMV (Kempact RA) Operating Manual 1922090 R05, Kemppi Oy, 2021, PDF download linked from the Kemppi user documentation
- MXF 63, 65, 67 FastMig wire feeders Operating Manual 1923680 R08, Kemppi Oy, 2021, PDF download linked from the Kemppi user documentation
- MinarcMig 190 AUTO, 220 AUTO Operating Manual 1922330 R00, Kemppi Oy, PDF download linked from the Kemppi user documentation
- Kemppi user documentation index, kemppi.com
- FastMig M 320, 420, 520 Operating Manual 1903470 R04, Kemppi Oy, PDF download linked from the Kemppi user documentation
See the moment the cell stopped
Fabrico, a light MES with computer vision, syncs camera footage with machine and timeline data, so you can replay the exact moment the cell stopped and review the cause next to the welder's error. Cameras also catch short stops and a line that is switched on but not producing, the losses nobody writes down. Machines connect through a PLC, a Fabrico IoT device or an AI camera.
Book a Fabrico demoRelated: Miller welder error codes · Lincoln Power Wave error codes · Fronius TPS error codes · spot welder · plasma cutter · how to track downtime
Other alarm code lookups: FANUC: servo amplifier · spindle amplifier | Siemens: MICROMASTER 440 · MASTERDRIVES · SINAMICS G120 · SINAMICS V90 servo · SINAMICS V20 · SINAMICS G110 | ABB: ACS550 drive · ACS800 drive · robot IRC5 · DCS800 DC drive | Okuma: OSP alarms | Haas: alarm lookup | Mitsubishi: MELSERVO servo · FR-D700 and FR-E700 inverters · FX PLC | Allen-Bradley: Kinetix and Ultra3000 · MicroLogix · PowerFlex 753 and 755 · PowerFlex 70 and 700 · 1336 and 1305 · SMC soft starters | Yaskawa: V1000 drive · SERVOPACK servo · Motoman robot | Delta: VFD drives · ASDA servo | Eaton: DC1 and SVX9000 drives | Control Techniques: Commander SK and M200 | Kollmorgen: AKD servo | Lenze: SMVector, 8200, 8400, i500 | Magnetek: IMPULSE and DSD 412 | Omron: MX2 and RX inverters · G5 and 1S servo · CP1 and CJ2 PLC | WEG: CFW500, CFW300, CFW11, CFW08 | Hitachi: WJ200 inverter · SJ700 and SJ-P1 | Toshiba: E3, Q9, P9, S15, nC3, AS3 | AutomationDirect: GS10, GS20, GS4, GS1 to GS3 | Festo: CMMT servo drives | Videojet: 1000 Line CIJ printers | Lincoln Electric: Power Wave welders | Fronius: TPS and TPS/i welders | Beckhoff: TwinCAT ADS, NC and BK1120 | Universal Robots: CB3 and e-Series cobots | Pilz: PNOZ safety relays | SICK: S3000, S300, microScan3 | SANYO DENKI: SANMOTION servo | Parker: SSD 590+, 690+, AC10 | KEB: COMBIVERT F5 | Epson: robot RC700, RC90 | B&R: ACOPOS servo | Schneider Electric: Lexium 32 servo | Bosch Rexroth: IndraDrive | Vacon: NX, VACON 100 and 20 | Fuji Electric: FRENIC-Mini, Multi, Ace, MEGA | LS Electric: S100, G100, iG5A | Panasonic: MINAS A6 and A5 servo | Invertek: Optidrive E3, P2, Eco | SEW-Eurodrive: MOVITRAC B and MOVIDRIVE B | HEIDENHAIN: iTNC 530 and TNC | NORD: NORDAC SK 200E and SK 500E | Baldor: Series 15H and 18H drives | Atlas Copco: Elektronikon compressors and VSD | Inovance: MD290, MD200, MD500, MD310 | INVT: Goodrive GD20, GD200A, GD350 | TECO: A510, F510, E510, L510s | Hyundai: N700E, N700, N300 inverters | Ingersoll Rand: Intellisys compressors | Miller: Welders | Benshaw: RediStart soft starters | Sullair: Supervisor and STS compressors
Related tools: full troubleshooting directory · OEE calculator · downtime cost · MTBF / MTTR · glossary