Fronius TPS Error Codes
The service codes of Fronius TransPuls Synergic welding power sources (TPS 2700, TPS 3200, 4000 and 5000, TransSynergic 4000/5000, TIME 5000 Digital and CMT 4000 Advanced) and the TPS/i error numbers Fronius names for robot interfaces: what each one means, the likely causes, the first checks, and how to log it so it stops coming back.
How errors show
On the TPS 2700, TPS 3200/4000/5000 and TransSynergic 4000/5000 the control panel shows a service code split across its two digital displays, for example Err | 051 or tP1 | xxx, where xxx is a temperature value.
The error indicator lights up and the same message appears on every LocalNet device with a digital display, and a separate overtemperature indicator lights when the machine overheats.
Depending on the code it clears by itself (Err | 054, hot | H2O, overtemperature codes after cooling), is acknowledged with the Store button or the Feeder inching button, or needs the power source switched off and back on.
On the TPS/i, malfunctions, warnings and status codes appear on the display as plain text dialogues and are stored in the logbook (Defaults / Documentation / Logbook), the SmartManager website shows a red error line with the error number, and a robot or PLC receives them as the Error number and Warning number signals.
A TPS/i error is reset with the Error reset signal, or via the torch trigger, display or interface, after the cause has been fixed.
The housing screws are the ground conductor connection for the housing, so never replace them with screws that lack a reliable ground conductor connection.
Fronius states that this work must only be done by technically trained and qualified personnel, and that any service code not described in the manual can only be fixed by a service technician: note the message, serial number and configuration and contact Fronius After-Sales Service.
Follow lockout/tagout and your site's safe-work procedures, and check the manual for your exact model before you act.
Quick lookup
Service codes and errors stop the weld and the cell, so in OEE they are availability losses; a weld cut short also costs quality.
Type a code or a word (mains, gas, overtemperature, wire) to filter the list. Click a code for its causes and first checks. Model TPS means the TPS 2700 to 5000 family, TPS/i the TPS 320i to 600i; TPS/i Limit Monitoring numbers 50 and 51 are not the same as Err | 050 and Err | 051 on the TPS.
70 codes
| Code | Model | Name |
|---|---|---|
| -St | oP- | TPS | Robot not ready |
| dsP | A21 | TPS | LHSB link lost during parallel or TimeTwin operation |
| dSP | Axx, Cxx, Exx, Sy, nSy | TPS | Fault in the central control and regulation unit |
| E-S | toP | TPS | External stop has tripped |
| EFd | 8.1, EFd | 8.2 | TPS | Fault in the wire feed system (overcurrent in wire-feed unit drive) |
| EFd | 9.1 | TPS | External supply voltage below tolerance range |
| EFd | 9.2 | TPS | External supply voltage above tolerance range |
| EFd | 12.1 | TPS | No actual speed value from the wire-feed unit motor |
| EFd | 12.2 | TPS | No actual speed value from the push-pull unit motor |
| EFd | 15.1 | TPS | Wire buffer empty |
| EFd | 15.2 | TPS | Wire buffer full |
| EFd | 15.3 | TPS | No wire buffer available |
| EFd | 30.1 | TPS | LHSB connection to power source missing |
| EFd | 30.3 | TPS | LHSB connection to CMT drive unit missing |
| EFd | 31.1 | TPS | Rotor calibration on the CMT drive unit failed |
| EFd | 31.2 | TPS | Rotor calibration on the CMT drive unit is running |
| EiF XX.Y | TPS | Interface error |
| Err | 049 | TPS | Phase failure |
| Err | 050 | TPS | Intermediate circuit balance error |
| Err | 051 | TPS | Mains undervoltage |
| Err | 052 | TPS | Mains overvoltage |
| Err | 054 | TPS | Wire stuck in the solidifying weld pool |
| Err | 056 | TPS | Wire end detected or VR 1500 / VR 1530 wire-feed protection tripped |
| Err | 062 | TPS | TP 08 remote control overheated |
| Err | 069 | TPS | Illegal mode change during welding |
| Err | 70.x | TPS | Fault in digital gas sensor |
| Err | 71.x | TPS | Set limits exceeded or not reached |
| Err | 77.x | TPS | Wire-feed motor current limit exceeded |
| Err | bPS | TPS | Fault in power module |
| Err | Cfg | TPS | No LHSB link after switch-on (parallel or TimeTwin) |
| Err | IP | TPS | Primary overcurrent |
| Err | PE | TPS | Earth current watchdog tripped |
| Err | tJo | TPS | JobMaster torch temperature sensor faulty |
| hot | H2O | TPS | Cooling unit thermostat has tripped |
| no | Arc | TPS | Arc break |
| no | GAS | TPS | No gas pressure (gas watchdog) |
| no | IGn | TPS | Ignition time-out |
| no | H2O | TPS | Cooling unit flow watchdog triggered |
| no | Prg | TPS | No preconfigured program selected |
| r | E30 | TPS | r calibration: no contact with the workpiece |
| r | E31 | TPS | r calibration interrupted by repeated torch trigger |
| r | E32 | TPS | r calibration: ground cable, current cable or hosepack defective |
| r | E33, r | E34 | TPS | r calibration: poor contact between contact tube and workpiece |
| tJO | xxx | TPS | JobMaster welding torch overheating |
| tP1 to tP6 | xxx | TPS | Overtemperature in the primary circuit |
| tS1 to tS3 | xxx | TPS | Overtemperature in the secondary circuit |
| tSt | xxx | TPS | Overtemperature in the control circuit |
| Err | Eto | TPS | Incorrect measurement during push-pull calibration |
| St1 | E 1 to St1 | E 6 | TPS | Push-pull open-circuit calibration: no actual speed value |
| St1 | E 16, St2 | E 16 | TPS | Push-pull calibration interrupted by quick-stop |
| St2 | E 7 | TPS | Open-circuit push-pull calibration not done |
| St2 | E 8, St2 | E 12 | TPS | Push-pull engaged calibration: no actual speed value from wire-feed motor |
| St2 | E 9, St2 | E 13 | TPS | Push-pull engaged calibration: no actual speed value from push-pull motor |
| St2 | E 10, St2 | E 14 | TPS | Push-pull engaged calibration: wire-feed motor current out of range |
| St2 | E 11, St2 | E 15 | TPS | Push-pull engaged calibration: push-pull motor current out of range |
| 6451 | TPS/i | Phase error (incorrect power supply) |
| 6515 | TPS/i | Phase error (incorrect power supply) |
| 1334 | TPS/i | Short circuit between contact tip and welding ground during active WireSense/teach process |
| 1340 | TPS/i | Maximum number of movement cycles on isolating materials achieved |
| 16680 | TPS/i | Increased motor force / unstable wirefeed process detected during isolated mode |
| 19 | TPS/i | Lower voltage limit undershot |
| 20 | TPS/i | Upper voltage limit exceeded |
| 21 | TPS/i | Lower current limit undershot |
| 22 | TPS/i | Upper current limit exceeded |
| 23 | TPS/i | Lower wirefeeder limit undershot |
| 24 | TPS/i | Upper wirefeeder limit exceeded |
| 47 | TPS/i | Lower energy limit not reached |
| 48 | TPS/i | Upper energy limit exceeded |
| 50 | TPS/i | Lower welding time limit not reached |
| 51 | TPS/i | Upper welding time limit exceeded |
Each code: causes and first checks
-St | oP-: Robot not ready
Hits OEE: AvailabilityWhat it means: Shown when the power source is run with a robot interface or a field bus and the robot control has not signalled that the robot is ready.[1]
Likely causes
- Robot ready signal not set by the robot control
First checks, in this order
- Set the Robot ready signal from the robot control.
- With a ROB 5000 robot interface or a field bus coupler for robot control, also send the Source error reset signal.
dsP | A21: LHSB link lost during parallel or TimeTwin operation
Hits OEE: AvailabilityWhat it means: Only in parallel operation or TimeTwin Digital mode. The power source is set for parallel operation (setup parameter P-C = ON) or TimeTwin Digital (setup parameter T-C = ON), and the LHSB link was disconnected or became faulty while the power source was switched on.[1]
Device response: Reset by switching the power source off and back on.
Likely causes
- LHSB link unplugged while the power source was on
- Faulty LHSB link
First checks, in this order
- Switch the power source off and back on to reset the code.
- If needed, restore or repair the LHSB link.
dSP | Axx, Cxx, Exx, Sy, nSy: Fault in the central control and regulation unit
Hits OEE: AvailabilityWhat it means: The power source reports an internal fault in its central control and regulation unit. Fronius prints the same text for dSP | Axx, dSP | Cxx, dSP | Exx, dSP | Sy and dSP | nSy.[1]
Likely causes
- Internal fault in the central control and regulation unit
First checks, in this order
- Fronius only lists one remedy: contact After-Sales Service.
- Note the code, the serial number and the configuration of the power source, then contact Fronius After-Sales Service with a detailed description.
E-S | toP: External stop has tripped
Hits OEE: AvailabilityWhat it means: Only with the External stop or External stop with inching enabled options. The external stop input has tripped and the machine is stopped.[1]
Device response: Acknowledge via the robot control unit and re-apply the 24 V SELV safety voltage.
Likely causes
- External stop circuit opened
- 24 V SELV safety voltage on the external stop removed
First checks, in this order
- Find and clear whatever tripped the external stop.
- Acknowledge the code from the robot control unit.
- Re-apply the 24 V SELV safety voltage.
EFd | 8.1, EFd | 8.2: Fault in the wire feed system (overcurrent in wire-feed unit drive)
Hits OEE: AvailabilityWhat it means: The wire-feed drive is drawing too much current. Fronius prints the same text for the general code EFd | xx.x.[1]
Likely causes
- Hosepack laid with tight bends
- Kinks or dirt in the inner liner
- Wrong contact pressure on the 2-roller or 4-roller drive
- Wire-feed unit motor sticking or defective
First checks, in this order
- Lay the hosepack in as straight a line as possible.
- Check the inner liner for kinks and dirt.
- Check the contact pressure on the 2-roller or 4-roller drive.
- Check the wire-feed unit motor and replace it if it sticks or is defective.
EFd | 9.1: External supply voltage below tolerance range
Hits OEE: AvailabilityWhat it means: The external supply voltage has dropped below the tolerance range.[1]
Likely causes
- External supply voltage too low
- Wire-feed unit motor sticking or defective (listed by Fronius as a second cause)
First checks, in this order
- Measure the external supply voltage.
- Check the wire-feed unit motor and replace it if it sticks or is defective.
EFd | 9.2: External supply voltage above tolerance range
Hits OEE: AvailabilityWhat it means: The external supply voltage has risen above the upper limit of the tolerance range.[1]
Likely causes
- External supply voltage too high
First checks, in this order
- Measure the external supply voltage.
EFd | 12.1: No actual speed value from the wire-feed unit motor
Hits OEE: AvailabilityWhat it means: The power source receives no actual rotational speed value from the wire-feed unit motor.[1]
Likely causes
- Faulty actual-value pick-up on the wire-feed motor
- Damaged cable or connection to the pick-up
First checks, in this order
- Check the actual-value pick-up and the cable connections to and from it.
- Replace the pick-up or cable if faulty.
EFd | 12.2: No actual speed value from the push-pull unit motor
Hits OEE: AvailabilityWhat it means: The power source receives no actual rotational speed value from the push-pull unit motor.[1]
Likely causes
- Faulty actual-value pick-up on the push-pull motor
- Damaged cable or connection to the pick-up
First checks, in this order
- Check the actual-value pick-up and the cable connections to and from it.
- Replace the pick-up or cable if faulty.
EFd | 15.1: Wire buffer empty
Hits OEE: AvailabilityWhat it means: The wire buffer has run empty.[1]
Device response: Acknowledge with the Feeder inching button once the cause is fixed.
Likely causes
- Counter lever on the main wire-feed unit open
- Main wire-feed unit slipping
- End of wire reached
First checks, in this order
- Close the counter lever on the main wire-feed unit.
- Check the wearing parts of the wire-feed unit, use suitable feed rollers, reduce the wire brake force and increase the contact pressure on the main wire-feed unit.
- Check that enough wire is left.
- Acknowledge the code with the Feeder inching button.
EFd | 15.2: Wire buffer full
Hits OEE: AvailabilityWhat it means: The wire buffer is full.[1]
Device response: Acknowledge with the Feeder inching button once the cause is fixed.
Likely causes
- Counter lever on the push-pull unit open
- Push-pull unit slipping
- Arc not igniting because of a poor ground (earth) connection
- Arc not igniting because the wrong welding program is selected
First checks, in this order
- Close the counter lever on the push-pull unit.
- Check the wire feed wearing parts, use suitable feed rollers and increase the contact pressure on the push-pull unit.
- Check the ground (earth) connection.
- Select the welding program that matches the wire diameter and material in use.
- Acknowledge the code with the Feeder inching button.
EFd | 15.3: No wire buffer available
Hits OEE: AvailabilityWhat it means: The power source cannot find the wire buffer.[1]
Likely causes
- Connection to the wire buffer missing
First checks, in this order
- Check the connection to the wire buffer.
- Check the wire buffer control line.
EFd | 30.1: LHSB connection to power source missing
Hits OEE: AvailabilityWhat it means: The wire-feed system has lost its LHSB connection to the power source.[1]
Likely causes
- LHSB connection to the power source unplugged or faulty
First checks, in this order
- Check the LHSB connection to the power source.
EFd | 30.3: LHSB connection to CMT drive unit missing
Hits OEE: AvailabilityWhat it means: The LHSB connection to the CMT drive unit is missing. Only on systems with a CMT drive unit.[1]
Likely causes
- LHSB connection to the CMT drive unit unplugged or faulty
First checks, in this order
- Check the LHSB connection to the CMT drive unit.
EFd | 31.1: Rotor calibration on the CMT drive unit failed
Hits OEE: AvailabilityWhat it means: The rotor calibration of the CMT drive unit did not succeed. Only on systems with a CMT drive unit.[1]
Likely causes
- Rotor calibration of the CMT drive unit failed
First checks, in this order
- Switch the power source off and back on.
- If EFd | 31.1 remains, switch the power source off, disengage the CMT drive unit and switch the power source back on.
- If it still appears, contact Fronius After-Sales Service.
EFd | 31.2: Rotor calibration on the CMT drive unit is running
Hits OEE: AvailabilityWhat it means: Status message: the CMT drive unit is performing its rotor calibration.[1]
Likely causes
- Rotor calibration in progress
First checks, in this order
- Wait for the rotor calibration to finish.
EiF XX.Y: Interface error
Hits OEE: AvailabilityWhat it means: An error reported by the robot interface. The values XX and Y are explained in the operating instructions of the robot interface.[1]
Likely causes
- Fault reported by the robot interface
First checks, in this order
- Look up XX and Y in the operating instructions for the robot interface and follow the remedy given there.
Err | 049: Phase failure
Hits OEE: AvailabilityWhat it means: The power source has detected that a mains phase is missing.[1]
Likely causes
- Blown mains fuse
- Damaged mains lead
- Faulty mains plug
First checks, in this order
- Check the mains fuse.
- Check the mains lead.
- Check the mains plug.
Err | 050: Intermediate circuit balance error
Hits OEE: AvailabilityWhat it means: The power source reports a balance error in its intermediate (DC link) circuit.[1]
Likely causes
- Internal fault in the intermediate circuit
First checks, in this order
- Fronius only lists one remedy: contact After-Sales Service.
- Note the code, the serial number and the configuration of the power source, then contact Fronius After-Sales Service with a detailed description.
Err | 051: Mains undervoltage
Hits OEE: AvailabilityWhat it means: The mains voltage has fallen below the tolerance range of the power source.[1][5]
Also on: TransSteel 3500 / 5000 Syn shows the same condition as Err | 51 (Fronius adds: contact After-Sales Service if it keeps recurring).
Likely causes
- Mains voltage too low
First checks, in this order
- Measure and check the mains voltage.
Err | 052: Mains overvoltage
Hits OEE: AvailabilityWhat it means: The mains voltage has risen above the tolerance range of the power source.[1][5]
Also on: TransSteel 3500 / 5000 Syn shows the same condition as Err | 52 (Fronius adds: contact After-Sales Service if it keeps recurring).
Likely causes
- Mains voltage too high
First checks, in this order
- Measure and check the mains voltage.
Err | 054: Wire stuck in the solidifying weld pool
Hits OEE: AvailabilityWhat it means: The wire-stick control function has detected the wire electrode sticking in the solidifying weld pool within 750 ms after the end of welding. Available when a robot interface or field bus system is connected.[1]
Device response: Output after the end of welding; the code does not need to be acknowledged. The power source is ready again once the wire is cut free.
Likely causes
- Wire electrode stuck in the weld pool at the end of the seam
First checks, in this order
- Make sure the Arc on signal is not set while you fix it, otherwise welding starts again as soon as the wire is freed.
- Cut off the sticking end of the wire electrode.
Err | 056: Wire end detected or VR 1500 / VR 1530 wire-feed protection tripped
Hits OEE: AvailabilityWhat it means: The Wire-end check option has detected the end of the wire electrode, or a protection on a VR 1500 - 11 / 12 / 30 or VR 1530 wire-feed unit has tripped.[1]
Device response: Wire feed halts when the wire-end sensor triggers, either at once or after the current seam depending on the FCO setup parameter (with the noE setting, field bus only, the alarm goes only to the robot control). Acknowledge with the Store button.
Likely causes
- End of wire electrode reached (Wire-end check option)
- Additional fan filter of the VR 1500 - 11 / 12 / 30 contaminated, so the power electronics overheat and their temperature switch trips
- Ambient temperature too high at the VR 1500 - 11 / 12 / 30
- Motor current too high on the VR 1500 - 11 / 12 / 30, for example from wire feed problems
- VR 1530 wire-feed unit cover open or interlock release handles not snapped into place
First checks, in this order
- Fit a new wirespool and feed the wire electrode into the hosepack.
- Clean or replace the additional fan filter of the VR 1500.
- Lower the ambient temperature or move the welding machine to a cooler place.
- Check the wire feed conditions and correct any faults.
- Close the VR 1530 cover properly with the interlock handles engaged.
- Acknowledge Err | 056 with the Store button.
Err | 062: TP 08 remote control overheated
Hits OEE: AvailabilityWhat it means: The TP 08 remote control has overheated. E62 is shown on the TP 08 at the same time.[1]
Likely causes
- Overheating of the TP 08 remote control
First checks, in this order
- Let the TP 08 remote control cool down.
Err | 069: Illegal mode change during welding
Hits OEE: AvailabilityWhat it means: A mode change was attempted while welding, for example changing from a MIG/MAG job to a TIG job.[1]
Likely causes
- Mode or job type changed during welding
First checks, in this order
- Start the welding action again.
- Do not switch between job types (for example MIG/MAG and TIG) while welding.
Err | 70.x: Fault in digital gas sensor
Hits OEE: AvailabilityWhat it means: The digital gas sensor reports a fault: Err 70.1 gas sensor not found, Err 70.2 no gas, Err 70.3 calibration error, Err 70.4 solenoid valve faulty, Err 70.5 solenoid valve not found.[1]
Likely causes
- Gas sensor not found (70.1)
- No gas (70.2)
- Gas sensor calibration error (70.3)
- Gas solenoid valve faulty (70.4)
- Gas solenoid valve not found (70.5)
First checks, in this order
- Check the gas supply.
- Note the sub-code (70.1 to 70.5) to narrow down the cause.
Err | 71.x: Set limits exceeded or not reached
Hits OEE: AvailabilityWhat it means: The welding current or voltage left the limits that were set: Err 71.1 current limit exceeded, Err 71.2 current limit not reached, Err 71.3 voltage limit exceeded, Err 71.4 voltage limit not reached.[1]
Likely causes
- Welding current above or below the set limit (71.1, 71.2)
- Welding voltage above or below the set limit (71.3, 71.4)
First checks, in this order
- Check the quality of the weld seam.
- Note the sub-code to see which limit was crossed.
Err | 77.x: Wire-feed motor current limit exceeded
Hits OEE: AvailabilityWhat it means: The current limit set for a wire-feed motor has been exceeded: Err 77.7 wire-feed unit motor current exceeded, Err 77.8 PPU (push-pull unit) motor current exceeded.[1]
Likely causes
- Too much resistance in the wire feed path (feed rollers, inner liner, inlet or outlet nozzles)
First checks, in this order
- Check the wire-feed components: feed rollers, inner liner, inlet and outlet nozzles.
- Check the quality of the weld seam.
Err | bPS: Fault in power module
Hits OEE: AvailabilityWhat it means: The power source reports a fault in its power module.[1]
Likely causes
- Internal fault in the power module
First checks, in this order
- Fronius only lists one remedy: contact After-Sales Service.
- Note the code, the serial number and the configuration of the power source, then contact Fronius After-Sales Service with a detailed description.
Err | Cfg: No LHSB link after switch-on (parallel or TimeTwin)
Hits OEE: AvailabilityWhat it means: Only in parallel operation or TimeTwin Digital mode. The power source is set for parallel operation (P-C = ON) or TimeTwin Digital (T-C = ON), but after switch-on it could not establish an LHSB link because the link was detached or faulty.[1]
Device response: Reset by switching the power source off and back on.
Likely causes
- LHSB link detached before switch-on
- Faulty LHSB link
First checks, in this order
- Switch the power source off and back on to reset the code.
- If needed, restore or repair the LHSB connection.
Err | IP: Primary overcurrent
Hits OEE: AvailabilityWhat it means: The power source has detected an overcurrent in its primary (mains side) circuit.[1][5]
Also on: TransSteel 3500 / 5000 Syn prints Err | IP with a different meaning: primary overvoltage. There, check the mains voltage, switch off for 10 seconds and back on, and contact After-Sales Service if it persists.
Likely causes
- Internal fault on the primary side of the power source
First checks, in this order
- Fronius only lists one remedy: contact After-Sales Service.
- Note the code, the serial number and the configuration of the power source, then contact Fronius After-Sales Service with a detailed description.
Err | PE: Earth current watchdog tripped
Hits OEE: AvailabilityWhat it means: The earth current watchdog has triggered the safety cut-out of the power source.[1][5]
Also on: TransSteel 3500 / 5000 Syn: same code and meaning; that manual also says to place the power source on an insulating surface and to connect the grounding cable to a part of the workpiece closer to the arc.
Device response: Safety cut-out of the power source; switch off, wait 10 seconds, switch on.
Likely causes
- Welding current flowing through an unintended earth path
First checks, in this order
- Switch the power source off, wait 10 seconds and switch it back on.
- If the error keeps coming back after several tries, contact Fronius After-Sales Service.
Err | tJo: JobMaster torch temperature sensor faulty
Hits OEE: AvailabilityWhat it means: The temperature sensor in the JobMaster welding torch is faulty.[1]
Likely causes
- Faulty temperature sensor in the JobMaster torch
First checks, in this order
- Fronius only lists one remedy: contact After-Sales Service.
- Note the code, the serial number and the configuration of the power source, then contact Fronius After-Sales Service with a detailed description.
hot | H2O: Cooling unit thermostat has tripped
Hits OEE: AvailabilityWhat it means: The thermostat on the cooling unit has tripped because the coolant is too hot.[1][5]
Also on: TransSteel 3500 / 5000 Syn: same code (coolant temperature too high); that manual adds cleaning the cooler and checking that the cooling unit fan works.
Device response: Clears by itself once the coolant has cooled down.
Likely causes
- Coolant temperature too high
First checks, in this order
- Wait until the cooling phase ends and hot | H2O is no longer displayed.
- With a ROB 5000 or a field bus coupler for robot control, set the Source error reset signal before welding again.
no | Arc: Arc break
Hits OEE: AvailabilityWhat it means: The arc break watchdog has switched the machine off: the arc broke and no current started flowing again within the time set in the Setup menu (parameter Arc, factory setting OFF).[1]
Device response: The system cuts out automatically; press the torch trigger again to start welding.
Likely causes
- Wire stick-out too long
- Dirty workpiece surface
- Arc break watchdog enabled with a short time setting
First checks, in this order
- Shorten the wire stick-out.
- Clean the surface of the workpiece.
- Press the torch trigger again to restart.
no | GAS: No gas pressure (gas watchdog)
Hits OEE: AvailabilityWhat it means: The Gas watchdog option has detected a loss of gas pressure.[1][5]
Also on: TransSteel 3500 / 5000 Syn: same code and meaning; there it is reset by pressing any button.
Device response: Acknowledge with the Store button once gas pressure is back.
Likely causes
- Gas cylinder empty
- Cylinder valve or pressure regulator closed
First checks, in this order
- Connect a new gas cylinder.
- Open the gas cylinder valve and the pressure regulator.
- Acknowledge no | GAS with the Store button.
no | IGn: Ignition time-out
Hits OEE: AvailabilityWhat it means: The Ignition time-out function is active and no current started flowing before the length of wire set in the Setup menu (parameter Ito) had been fed, so the safety cut-out tripped. E55 is shown on the JobMaster torch and on the field bus module.[1][5]
Also on: TransSteel 3500 / 5000 Syn: same code and meaning.
Device response: Safety cut-out; press the torch trigger again for a new ignition attempt.
Likely causes
- Wire stick-out too long
- Dirty workpiece surface
- Ito wire length set too short for the application
First checks, in this order
- Shorten the wire stick-out.
- Press the torch trigger again.
- Clean the surface of the workpiece.
- If needed, increase the Ito setting in Setup menu level 2.
no | H2O: Cooling unit flow watchdog triggered
Hits OEE: AvailabilityWhat it means: The flow watchdog of the cooling unit has been triggered because coolant flow is too low. The setup parameter C-t sets the time from the flow watchdog triggering until no | H2O is shown.[1][5]
Also on: TransSteel 3500 / 5000 Syn: same code (coolant flow rate too low).
Device response: Acknowledge with the Store button once flow is restored.
Likely causes
- Coolant level too low
- Air in the cooling circuit
- Fault in the cooling unit
First checks, in this order
- Check the cooling unit.
- Top up the coolant and bleed the water flow if needed (see the cooling unit operating instructions).
- Acknowledge the error with the Store button.
no | Prg: No preconfigured program selected
Hits OEE: AvailabilityWhat it means: No preconfigured program has been selected, so the power source has no welding program to run.[1][5]
Also on: TransSteel 3500 / 5000 Syn: same code and meaning.
Likely causes
- No preconfigured program has been selected
First checks, in this order
- Select a configured program.
r | E30: r calibration: no contact with the workpiece
Hits OEE: AvailabilityWhat it means: During measurement of the welding circuit resistance r the machine cannot make contact with the workpiece.[1]
Likely causes
- Grounding (earthing) cable not connected
- Contact tube not touching the workpiece firmly
First checks, in this order
- Connect the grounding (earthing) cable.
- Make a tight connection between the contact tube and the workpiece.
r | E31: r calibration interrupted by repeated torch trigger
Hits OEE: AvailabilityWhat it means: The welding circuit resistance measurement was interrupted because the torch trigger was pressed repeatedly.[1]
Likely causes
- Torch trigger pressed more than once during the measurement
First checks, in this order
- Make a tight connection between the contact tube and the workpiece.
- Press the torch trigger once only.
r | E32: r calibration: ground cable, current cable or hosepack defective
Hits OEE: AvailabilityWhat it means: The measured welding circuit resistance is below 0.5 milliohm or above 30 milliohm, which points to a defective cable or hosepack.[1]
Likely causes
- Defective grounding (earthing) cable
- Defective current cable
- Defective hosepack
First checks, in this order
- Check the grounding (earthing) cable, the current cable and the hosepack, and replace if needed.
r | E33, r | E34: r calibration: poor contact between contact tube and workpiece
Hits OEE: AvailabilityWhat it means: The welding circuit resistance measurement found poor contact between the contact tube and the workpiece. Fronius prints the same text for r | E33 and r | E34.[1]
Likely causes
- Dirty contact point
- Loose contact tube
- Poor grounding (earthing) connection
First checks, in this order
- Clean the point of contact.
- Tighten the contact tube.
- Check the grounding (earthing) connection.
tJO | xxx: JobMaster welding torch overheating
Hits OEE: AvailabilityWhat it means: The JobMaster welding torch is overheating; xxx is a temperature value. E66 is shown on the JobMaster at the same time.[1]
Device response: Acknowledge with the Store button after the torch has cooled.
Likely causes
- Overheating of the JobMaster welding torch
First checks, in this order
- Let the torch cool down.
- Acknowledge the error with the Store button.
tP1 to tP6 | xxx: Overtemperature in the primary circuit
Hits OEE: AvailabilityWhat it means: Overtemperature in the primary circuit of the power source; xxx is a temperature value. Fronius prints the same text for tP1, tP2, tP3, tP4, tP5 and tP6.[1]
Device response: Thermostatic safety cut-out stops welding current; the power source comes back on by itself after the cooling phase.
Likely causes
- Overload: duty cycle exceeded
- Limited supply of cooling air
- Faulty fan in the power source
First checks, in this order
- Let the power source cool down; it comes back on by itself after the cooling phase.
- Take the duty cycle into account.
- Remove the air filter at the rear of the housing from the side and clean it, and keep the cooling air ducts free.
- If the fan is faulty, contact Fronius After-Sales Service.
tS1 to tS3 | xxx: Overtemperature in the secondary circuit
Hits OEE: AvailabilityWhat it means: Overtemperature in the secondary circuit of the power source; xxx is a temperature value. Fronius prints the same text for tS1, tS2 and tS3.[1]
Device response: Thermostatic safety cut-out stops welding current; the power source comes back on by itself after the cooling phase.
Likely causes
- Overload: duty cycle exceeded
- Limited supply of cooling air
- Faulty fan in the power source
First checks, in this order
- Let the power source cool down; it comes back on by itself after the cooling phase.
- Take the duty cycle into account.
- Clean the air filter at the rear of the housing and keep the cooling air ducts free.
- If the fan is faulty, contact Fronius After-Sales Service.
tSt | xxx: Overtemperature in the control circuit
Hits OEE: AvailabilityWhat it means: Overtemperature in the control circuit of the power source; xxx is a temperature value.[1]
Likely causes
- Overload: duty cycle exceeded
- Limited supply of cooling air
- Faulty fan in the power source
First checks, in this order
- Let the power source cool down.
- Clean the air filter at the rear of the housing and keep the cooling air ducts free.
- If the fan is faulty, contact Fronius After-Sales Service.
Err | Eto: Incorrect measurement during push-pull calibration
Hits OEE: AvailabilityWhat it means: A measurement went wrong while the push-pull unit was being calibrated with the drive units disengaged (open-circuit calibration).[1]
Likely causes
- Incorrect measurement during calibration
First checks, in this order
- Repeat the push-pull calibration.
St1 | E 1 to St1 | E 6: Push-pull open-circuit calibration: no actual speed value
Hits OEE: AvailabilityWhat it means: During open-circuit push-pull calibration (drive units disengaged) a motor gave no actual rotational speed value: at minimum wire feed speed for E 1, E 3 and E 4, at maximum wire feed speed for E 2, E 5 and E 6.[1]
Likely causes
- Motor delivers no actual speed value during calibration
First checks, in this order
- Repeat the push-pull calibration; if the message appears again, contact Fronius After-Sales Service.
St1 | E 16, St2 | E 16: Push-pull calibration interrupted by quick-stop
Hits OEE: AvailabilityWhat it means: The push-pull calibration was interrupted because quick-stop was activated by pressing the torch trigger.[1]
Likely causes
- Torch trigger pressed during calibration
First checks, in this order
- Repeat the push-pull calibration without pressing the torch trigger.
St2 | E 7: Open-circuit push-pull calibration not done
Hits OEE: AvailabilityWhat it means: The engaged push-pull calibration was started before the open-circuit calibration (drive units disengaged) had been carried out.[1]
Likely causes
- Open-circuit calibration skipped
First checks, in this order
- Carry out the push-pull calibration with the drive units disengaged (open-circuit) first, then the engaged calibration.
St2 | E 8, St2 | E 12: Push-pull engaged calibration: no actual speed value from wire-feed motor
Hits OEE: AvailabilityWhat it means: During engaged push-pull calibration the wire-feed unit motor gave no actual rotational speed value, at minimum wire feed speed (E 8) or maximum wire feed speed (E 12).[1]
Likely causes
- Wire-feed unit motor delivers no actual speed value
First checks, in this order
- Repeat the push-pull calibration; if the message appears again, contact Fronius After-Sales Service.
St2 | E 9, St2 | E 13: Push-pull engaged calibration: no actual speed value from push-pull motor
Hits OEE: AvailabilityWhat it means: During engaged push-pull calibration the push-pull unit motor gave no actual rotational speed value, at minimum wire feed speed (E 9) or maximum wire feed speed (E 13).[1]
Likely causes
- Push-pull motor delivers no actual speed value
- Faulty actual-value pick-up (named by Fronius for E 13)
First checks, in this order
- Repeat the push-pull calibration; if the message appears again, contact Fronius After-Sales Service.
St2 | E 10, St2 | E 14: Push-pull engaged calibration: wire-feed motor current out of range
Hits OEE: AvailabilityWhat it means: During engaged push-pull calibration the motor current of the wire-feed unit motor was outside the permitted range, at minimum wire feed speed (E 10) or maximum wire feed speed (E 14).[1]
Likely causes
- Wire-feed motors disengaged
- Wire feed problems
First checks, in this order
- Engage the drive units of both wire-feed motors.
- Lay the hosepack in as straight a line as possible.
- Check the inner liner for kinks or dirt.
- Check the contact pressure on the 2-roller or 4-roller drive of the push-pull unit.
- Repeat the push-pull calibration; if the message appears again, contact Fronius After-Sales Service.
St2 | E 11, St2 | E 15: Push-pull engaged calibration: push-pull motor current out of range
Hits OEE: AvailabilityWhat it means: During engaged push-pull calibration the motor current of the push-pull unit was outside the permitted range, at minimum wire feed speed (E 11) or maximum wire feed speed (E 15).[1]
Likely causes
- Wire-feed motors disengaged
- Wire feed problems
First checks, in this order
- Engage the drive units of both wire-feed motors.
- Lay the hosepack in as straight a line as possible.
- Check the inner liner for kinks or dirt.
- Check the contact pressure on the 2-roller or 4-roller drive of the push-pull unit.
- Repeat the push-pull calibration; if the message appears again, contact Fronius After-Sales Service.
6451: Phase error (incorrect power supply)
Hits OEE: AvailabilityWhat it means: A phase error has occurred, meaning the welding machine has an incorrect power supply. Fronius names error numbers 6451 and 6515 for this; the number is shown on the welding machine display and sent to the robot as the Error number signal.[4]
Also on: Fronius gives 6515 for the same phase error.
Likely causes
- Incorrect mains power supply to the welding machine, for example a missing phase
First checks, in this order
- Check the mains supply to the welding machine.
- On a robot cell, the Mains voltage status signal on the interface shows the phase error; on a TWIN system it goes High when either welding machine has a phase error, so check both.
6515: Phase error (incorrect power supply)
Hits OEE: AvailabilityWhat it means: A phase error has occurred, meaning the welding machine has an incorrect power supply. Fronius names error numbers 6451 and 6515 for this; the number is shown on the welding machine display and sent to the robot as the Error number signal.[4]
Also on: Fronius gives 6451 for the same phase error.
Likely causes
- Incorrect mains power supply to the welding machine, for example a missing phase
First checks, in this order
- Check the mains supply to the welding machine.
- On a robot cell, the Mains voltage status signal on the interface shows the phase error; on a TWIN system it goes High when either welding machine has a phase error, so check both.
1334: Short circuit between contact tip and welding ground during active WireSense/teach process
Hits OEE: AvailabilityWhat it means: During a WireSense or teach movement the torch was moved so far toward the workpiece that the contact tip made an electrical connection to it.[4]
Device response: The wire is retracted 40 mm and the error message is set.
Likely causes
- Torch moved too close to the workpiece during WireSense or teach
- Movement outside the WireSense length limits
First checks, in this order
- Move the torch back so the contact tip stays clear of the workpiece.
- Check the robot path against the WireSense measuring range and length limits.
1340: Maximum number of movement cycles on isolating materials achieved
Hits OEE: AvailabilityWhat it means: In WireSense Isolated mode more than 30 continuous movement cycles were made on non-conductive material, for example slag, silicate or oxide on the seam. At a slow search speed of 30 cm/min this is a silicate width of about 5 mm.[4]
Device response: The process stops automatically.
Likely causes
- Searching across slag, silicate or oxide deposits
- WireSense started on a non-conductive section
- Unstable wire feed in Isolated mode (see warning 16680), which can trigger 1340 incorrectly
First checks, in this order
- Start the WireSense process on a conductive section.
- Remove slag from the component or seam; the Slaghammer function only removes silicate on the wire tip.
- Check the logbook for warning 16680 before this error.
16680: Increased motor force / unstable wirefeed process detected during isolated mode
Warning: act before it becomes a stopWhat it means: In WireSense Isolated mode the welding machine saw unusual motor forces or wire speed profile, so the WireSense process is no longer running properly. If operation continues, error 1340 may be triggered incorrectly.[4]
Device response: Warning only; the running process is not aborted.
Likely causes
- Special torch types, for example very long or special torch geometries
- Special filler metals, for example CuMn13Al8
- Unsuitable inner liner or inner liner not matched to the wire diameter
- Uncommon wire diameters, for example 0.8 mm or 1.6 mm
First checks, in this order
- Check that the inner liner suits the wire diameter.
- Check the torch and filler metal against the cases Fronius lists.
- Clarify with Fronius Technical Support whether another system setup is possible or whether WireSense Isolated mode can be used.
19: Lower voltage limit undershot
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual voltage stayed below the lower voltage limit longer than the set reaction time (monitored per weld seam or job, in the main current phase). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual voltage outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
20: Upper voltage limit exceeded
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual voltage stayed above the upper voltage limit longer than the set reaction time (monitored per weld seam or job, in the main current phase). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual voltage outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
21: Lower current limit undershot
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual current stayed below the lower current limit longer than the set reaction time (monitored per weld seam or job, in the main current phase). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual current outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
22: Upper current limit exceeded
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual current stayed above the upper current limit longer than the set reaction time (monitored per weld seam or job, in the main current phase). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual current outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
23: Lower wirefeeder limit undershot
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual wirefeeder speed stayed below the lower wirefeeder limit longer than the set reaction time (monitored per weld seam or job, in the main current phase). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual wirefeeder speed outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
24: Upper wirefeeder limit exceeded
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual wirefeeder speed stayed above the upper wirefeeder limit longer than the set reaction time (monitored per weld seam or job, in the main current phase). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual wirefeeder speed outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
47: Lower energy limit not reached
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual energy input stayed below the lower energy limit longer than the set reaction time (monitored over the weld seam). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual energy input outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
48: Upper energy limit exceeded
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual energy input stayed above the upper energy limit longer than the set reaction time (monitored over the weld seam). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual energy input outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
50: Lower welding time limit not reached
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual welding time stayed below the lower welding time limit longer than the set reaction time (monitored over the weld seam). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual welding time outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
51: Upper welding time limit exceeded
Hits OEE: AvailabilityWhat it means: Limit Monitoring error message: the actual welding time stayed above the upper welding time limit longer than the set reaction time (monitored over the weld seam). Fronius lists this number under Limit Monitoring for the TPS/i.[4]
Device response: With the Limit reaction set to Error the welding machine stops welding, makes a logbook entry, marks the affected parameters red and outputs the error number at the interface. With Warning it keeps welding, makes a logbook entry and marks the parameters red, but outputs no warning number at the interface.
Likely causes
- Actual welding time outside the limits defined in the job
- Limits set from set values instead of measured actual values
- Job parameters changed without adjusting the limits
First checks, in this order
- Check the weld seam. If it is OK, review and adjust the limits; if it is not OK, check and adjust the welding parameters.
- Set limits from measured actual values (display, SmartManager or WeldCube Premium), not from set values.
Log it, or the same alarm comes back
A power source error stops the weld, and in a robot cell it stops the cell, so in OEE terms it is a breakdown. Log the code, the cell and the minutes lost, and the parts scrapped by a weld cut short, which count against quality.
- Reason code: the code plus the cell, for example Fronius tP1 overtemperature, weld cell 2, so a power source that overheats every afternoon shift shows up as a pattern.
- Loss bucket: a stop that needs a reset, a part or a technician is an availability loss (breakdown). Stops shorter than your micro-stop threshold go to performance (minor stops). The six big losses page shows where each one belongs.
- What to count: how often each code fires per week and the minutes it costs. Two numbers a week turn "that alarm comes up sometimes" into a ranked list. The MTBF and MTTR calculator and the downtime cost calculator do the math.
The free OEE tracker logs each stop with its reason and turns the week into a downtime Pareto, so the code that costs the most rises to the top.
fabrico.io has a MIG welder troubleshooting guide. A code tells you what the device detected, not what happened at the machine in the seconds before. Fabrico's camera-based OEE software syncs camera video with machine data, so you can replay the moment the cell stopped next to the welder's code.
Frequently asked questions
What does Err | 051 mean on a Fronius TPS welder?
Err | 051 is mains undervoltage: the mains voltage has fallen below the tolerance range of the power source. Measure and check the mains voltage. Its partner Err | 052 means mains overvoltage. On the TransSteel 3500 / 5000 Syn the same conditions show as Err | 51 and Err | 52, and Fronius adds that you should contact After-Sales Service if they keep recurring.
What does no | Prg mean on a Fronius TPS 4000 or 5000?
no | Prg means no preconfigured program has been selected. Select a configured welding program and the message clears. The TransSteel 3500 / 5000 Syn uses the same code with the same meaning.
What do tP1 and tS1 mean on a Fronius TPS?
They are overtemperature codes; the number after the bar is a temperature value. tP1 to tP6 mean overtemperature in the primary circuit, tS1 to tS3 in the secondary circuit, and tSt in the control circuit. Let the power source cool down; the thermostatic safety cut-out switches it back on after the cooling phase. Fronius lists overload (duty cycle exceeded), limited cooling air (clean the rear air filter, keep the ducts free) and a faulty fan as causes.
What does -St | oP- mean on a Fronius welding machine?
-St | oP- appears when the power source runs with a robot interface or field bus and the robot is not ready. Set the Robot ready signal from the robot control, and with a ROB 5000 or a field bus coupler for robot control also send the Source error reset signal.
What does Err | IP mean on a Fronius TPS?
On the TPS 2700, TPS 3200/4000/5000 family Err | IP means primary overcurrent, and Fronius only lists one remedy: contact After-Sales Service. Note the code, serial number and configuration first. Be careful when comparing machines: the TransSteel 3500 / 5000 Syn manual uses Err | IP for primary overvoltage instead.
Where do I find the error codes on a Fronius TPS 320i, 400i, 500i or 600i?
The TPS/i shows malfunctions, warnings and status codes on its display as plain text dialogues, keeps them in the logbook under Defaults / Documentation / Logbook, and shows a red error line with the error number on the SmartManager website. A robot or PLC receives the Error number and Warning number signals. Fronius' Help Center for welding also links to its online Error code analysis tool for looking up a number.
Sources
Codes and meanings follow the manufacturer documentation below. Wording is ours, simplified for the shop floor; the manual for your exact model and software version wins if it differs.
- TransSynergic 4000/5000, TransPuls Synergic 2700, TransPuls Synergic 3200/4000/5000, TIME 5000 Digital, CMT 4000 Advanced Operating Instructions (MIG/MAG power source), 42,0426,0001,EN, edition 024-15122020, hosted by Fronius (www.fronius.com)
- TPS 320i, TPS 400i, TPS 500i, TPS 600i Operating Instructions, online edition 048-22062026, hosted by Fronius (manuals.fronius.com)
- TPS 320i C Operating Instructions, online edition 048-22062026, hosted by Fronius (manuals.fronius.com)
- TPS/i Interface Signal Descriptions, user information, online edition 035-12062026, hosted by Fronius (manuals.fronius.com)
- TransSteel 3500 / 5000 Syn Operating Instructions, online edition 018-09122025, hosted by Fronius (manuals.fronius.com)
- Fronius Help Center, Welding, Help with error codes section, hosted by Fronius (www.fronius.com)
See the moment the cell stopped
Fabrico, a light MES with computer vision, syncs camera footage with machine and timeline data, so you can replay the exact moment the cell stopped and review the cause next to the welder's code. Cameras also catch short stops and a line that is switched on but not producing, the losses nobody writes down. Machines connect through a PLC, a Fabrico IoT device or an AI camera.
Book a Fabrico demoRelated: Lincoln Power Wave error codes · welding troubleshooting · spot welder · ABB robot error codes · industrial robot troubleshooting
Other alarm code lookups: FANUC: servo amplifier · spindle amplifier | Siemens: MICROMASTER 440 · MASTERDRIVES · SINAMICS G120 · SINAMICS V90 servo · SINAMICS V20 · SINAMICS G110 | ABB: ACS550 drive · ACS800 drive · robot IRC5 · DCS800 DC drive | Okuma: OSP alarms | Haas: alarm lookup | Mitsubishi: MELSERVO servo · FR-D700 and FR-E700 inverters · FX PLC | Allen-Bradley: Kinetix and Ultra3000 · MicroLogix · PowerFlex 753 and 755 · PowerFlex 70 and 700 · 1336 and 1305 | Yaskawa: V1000 drive · SERVOPACK servo · Motoman robot | Delta: VFD drives · ASDA servo | Eaton: DC1 and SVX9000 drives | Control Techniques: Commander SK and M200 | Kollmorgen: AKD servo | Lenze: SMVector, 8200, 8400, i500 | Magnetek: IMPULSE and DSD 412 | Omron: MX2 and RX inverters · G5 and 1S servo · CP1 and CJ2 PLC | WEG: CFW500, CFW300, CFW11, CFW08 | Hitachi: WJ200 inverter · SJ700 and SJ-P1 | Toshiba: E3, Q9, P9, S15, nC3, AS3 | AutomationDirect: GS10, GS20, GS4, GS1 to GS3 | Festo: CMMT servo drives | Videojet: 1000 Line CIJ printers | Lincoln Electric: Power Wave welders | Beckhoff: TwinCAT ADS, NC and BK1120 | Pilz: PNOZ safety relays | SICK: S3000, S300, microScan3 | SANYO DENKI: SANMOTION servo | Parker: SSD 590+, 690+, AC10 | KEB: COMBIVERT F5 | Epson: robot RC700, RC90 | B&R: ACOPOS servo | Schneider Electric: Lexium 32 servo | Bosch Rexroth: IndraDrive | Vacon: NX, VACON 100 and 20 | Fuji Electric: FRENIC-Mini, Multi, Ace, MEGA | LS Electric: S100, G100, iG5A | Panasonic: MINAS A6 and A5 servo | Invertek: Optidrive E3, P2, Eco | SEW-Eurodrive: MOVITRAC B and MOVIDRIVE B