Troubleshooting / Metal detector

Metal detector Troubleshooting

The most common metal detector problems on the plant floor, with the likely causes and the fix for each. Part of the OEE Lab directory of 301+ documented problems.

Not your exact symptom?

Describe it to the AI troubleshoot assistant and search all 301 documented problems.

Open the AI assistant

Problems on this page:

False rejects

Hits OEE: Performance

Symptoms: Good product rejected, high reject rate, yield loss.

Product effect not compensated
Set up product learn/phasing; use the correct memory.
Electrical noise or vibration
Improve grounding, shielding and mounting; reduce vibration.
Wet/foil product handling
Use the right frequency/mode for the product.

Prevention: Proper product setup, EMC/mounting, correct mode.

Missed contamination or low sensitivity

Hits OEE: Quality

Symptoms: Failed test-piece checks, contamination passes, safety risk.

Sensitivity set too low or wrong setup
Set sensitivity to the smallest reliable sphere; re-learn product.
Aperture too large for the pack
Match aperture to product size; centre the product.
Drift or head fault
Run routine test-piece checks; service the head.

Prevention: Correct sensitivity, right aperture, routine validation.

Reject mechanism fault

Hits OEE: Availability

Symptoms: Reject does not fire or misses, contaminated product passes, stops.

Air supply or actuator fault
Check air pressure and the reject actuator/valve.
Timing or sensor issue
Set reject timing; check the product-tracking sensor.
Bin-full or confirm-sensor fault
Empty the reject bin; check confirmation sensors.

Prevention: Air/actuator maintenance, reject-timing checks, fail-safe interlocks.

Metal detector troubleshooting FAQ

Metal detector: what causes false rejects, and how do I fix it?

Symptoms: Good product rejected, high reject rate, yield loss. Likely causes: Product effect not compensated; Electrical noise or vibration; Wet/foil product handling. Fixes: Set up product learn/phasing; use the correct memory. Improve grounding, shielding and mounting; reduce vibration. Use the right frequency/mode for the product. Prevention: Proper product setup, EMC/mounting, correct mode.

Metal detector: what causes missed contamination or low sensitivity, and how do I fix it?

Symptoms: Failed test-piece checks, contamination passes, safety risk. Likely causes: Sensitivity set too low or wrong setup; Aperture too large for the pack; Drift or head fault. Fixes: Set sensitivity to the smallest reliable sphere; re-learn product. Match aperture to product size; centre the product. Run routine test-piece checks; service the head. Prevention: Correct sensitivity, right aperture, routine validation.

Metal detector: what causes reject mechanism fault, and how do I fix it?

Symptoms: Reject does not fire or misses, contaminated product passes, stops. Likely causes: Air supply or actuator fault; Timing or sensor issue; Bin-full or confirm-sensor fault. Fixes: Check air pressure and the reject actuator/valve. Set reject timing; check the product-tracking sensor. Empty the reject bin; check confirmation sensors. Prevention: Air/actuator maintenance, reject-timing checks, fail-safe interlocks.

Guidance only. Always follow lockout/tagout and your site's safe-work procedures, and verify against OEM manuals before acting.

Stop the same fault coming back

Recurring metal detector stops usually trace to a cause you cannot see by hand. The partner we recommend is Fabrico: EU-built, so your production data stays in EU jurisdiction, with computer-vision true-cause of micro-stops, a closed loop from PLC-read OEE to an auto-routed work order, and ISO 27001 / 20000-1 / 9001 (supports audit-readiness).

See how Fabrico finds root cause
OEE Lab is built and operated by Fabrico. The directory stays free.

Related tools: full troubleshooting directory · OEE calculator · downtime cost · MTBF / MTTR · glossary

Methods that cut recurring stops: the six big losses · root cause analysis · preventive vs predictive maintenance · TPM · SMED & changeover