Troubleshooting / Deaerator

Deaerator Troubleshooting

The most common deaerator problems on the plant floor, with the likely causes and the fix for each. Part of the OEE Lab troubleshooting directory.

Not your exact symptom?

Describe it in the symptom finder and search the whole directory.

Open the symptom finder

Problems on this page:

Dissolved oxygen too high at the outlet

Hits OEE: Quality

Symptoms: Water leaving the deaerator carries more oxygen than the limit.

Steam or stripping gas flow too low
Check the steam or CO2 stripping flow against the design.
Vent valve closed or vent too small
Check the vent so stripped gases can leave the deaerator.
Water temperature too low in a thermal deaerator
Check the operating pressure and temperature.
Spray nozzles or trays damaged or fouled
Inspect the spray nozzles or trays at the next stop.

Prevention: Outlet dissolved oxygen measured continuously or each shift.

Pressure swinging

Hits OEE: Availability

Symptoms: Deaerator pressure swings, and the level and outlet oxygen become unstable.

Steam pressure control valve hunting
Tune the pressure control loop and check the valve for sticking.
Large swings in cold make-up water flow
Smooth the make-up flow control.
Condensate return arriving in surges
Check the condensate return pumps and their control.
Safety valve leaking
Have the safety valve checked; never gag or block a safety valve.

Prevention: Deaerator pressure trended.

Level control problems

Hits OEE: Availability

Symptoms: The storage tank level runs too high or too low.

Level transmitter fault or blocked impulse lines
Check the level transmitter against the gauge glass.
Make-up valve sticking
Service the make-up valve and its actuator.
Feed pump demand changing quickly
Check how boiler demand changes the outflow.
Overflow valve leaking
Check the overflow valve for passing water.

Prevention: Level trended and the gauge glass checked each shift.

Feed pump cavitation

Hits OEE: Availability

Symptoms: Boiler feed pumps below the deaerator cavitate, rattle or lose pressure.

Deaerator level too low
Check the level control.
Sudden pressure drop in the deaerator
Check the steam pressure control, since a drop flashes the water in the suction.
Suction strainer blocked
Clean the suction strainer.
Suction head too small for the water temperature
Check the installation height against the pump requirement.

Prevention: Pump vibration checked on a route.

Corrosion inside

Hits OEE: Availability

Symptoms: Inspection finds corrosion or cracking inside the deaerator.

Outlet oxygen high for long periods
Work through the dissolved oxygen causes.
Chemical dosing wrong
Check the oxygen scavenger and pH dosing.
Water pH low
Check the water treatment.
Inspections skipped
Inspect the vessel on the schedule the pressure vessel rules require.

Prevention: Internal inspection on the statutory schedule.

Steam use high

Hits OEE: Performance

Symptoms: The deaerator uses more steam than it used to.

Vent open further than needed
Set the vent to the opening that keeps the outlet oxygen in specification.
Insulation damaged
Repair the insulation on the vessel and pipework.
Make-up water colder than before
Check heat recovery on the make-up water.
Steam leaks
Fix leaking valves and flanges.

Prevention: Steam use trended monthly.

Water hammer

Hits OEE: Availability

Symptoms: Banging is heard in the deaerator or its steam lines.

Condensate collecting in the steam line
Check the drain points and traps on the steam line.
Valves opening or closing too fast
Slow the valve actuation where possible.
Cold water meeting steam in the wrong place
Check the spray valves and water distribution.
Level too high, flooding steam inlets
Check the level control.

Prevention: Water hammer events recorded with what was happening at the time.

Beverage water deaerator off specification

Hits OEE: Quality

Symptoms: Deaerated water for beverage production carries too much oxygen.

Vacuum too low in a vacuum deaerator
Check the vacuum pump and its seal water.
CO2 stripping gas flow too low
Check the CO2 supply and flow.
Water temperature outside the design
Check the water temperature at the inlet.
Flow above the design capacity
Check the flow against the deaerator rating.

Prevention: Outlet oxygen measured continuously.

Guidance only. Always follow lockout/tagout and your site's safe-work procedures, and verify against OEM manuals before acting.

Related equipment guides: steam boiler · beer filter · carbonator · centrifugal pump · steam trap

Stop the same fault coming back

Recurring deaerator stops usually trace to a cause you cannot see by hand. The partner we recommend is Fabrico: it tracks OEE and downtime live from PLCs, IoT sensors or AI cameras; where cameras are fitted, the video of a stop sits next to its machine data so the cause can be reviewed; and a technician opens the work order from the stop in the same system. Data is hosted in the AWS EU region, and Fabrico and the company behind it hold ISO/IEC 27001, ISO/IEC 20000-1 and ISO 9001.

Book a Fabrico demo
The directory stays free.

Related tools: full troubleshooting directory · OEE calculator · downtime cost · MTBF / MTTR · glossary

Methods that cut recurring stops: the six big losses · root cause analysis · preventive vs predictive maintenance · TPM · SMED & changeover