Carbonation too low
Hits OEE: QualitySymptoms: Lab or inline readings show less CO2 than the specification, and the drink tastes flat.
Prevention: CO2 level checked inline and confirmed in the lab on a schedule.
Carbonation varying
Hits OEE: QualitySymptoms: The CO2 level moves up and down through the run.
Prevention: CO2 trend reviewed after each run.
Foaming at the filler
Hits OEE: QualitySymptoms: Bottles or cans foam over at the filler and fill levels are low.
Prevention: Fill level rejects linked to product temperature and CO2 readings.
Dissolved oxygen too high
Hits OEE: QualitySymptoms: Oxygen readings in the product are above the limit, risking taste and shelf life.
Prevention: Dissolved oxygen measured on a schedule.
CO2 supply alarm
Hits OEE: AvailabilitySymptoms: The carbonator stops on low CO2 pressure.
Prevention: CO2 stock checked daily; rooms where CO2 can collect have gas detection, because CO2 can suffocate.
Product not cold enough
Hits OEE: QualitySymptoms: The product leaves the cooler above the set temperature.
Prevention: Product temperature recorded continuously.
Buffer tank pressure unstable
Hits OEE: QualitySymptoms: Pressure in the carbonated product tank rises and falls, and the filler struggles to run steadily.
Prevention: Tank pressure trended through the run.
Inline reading disagrees with the lab
Hits OEE: QualitySymptoms: The inline CO2 meter and the lab test give different results.
Prevention: Inline and lab results compared every week.
Cleaning results failing
Hits OEE: QualitySymptoms: Swabs or rinse checks fail after cleaning in place.
Prevention: Cleaning verified before production.
Related equipment guides: filling machine · chiller · heat exchanger · CIP system · can seamer · can filler · deaerator
Stop the same fault coming back
Recurring carbonator stops usually trace to a cause you cannot see by hand. The partner we recommend is Fabrico: it tracks OEE and downtime live from PLCs, IoT sensors or AI cameras; where cameras are fitted, the video of a stop sits next to its machine data so the cause can be reviewed; and a technician opens the work order from the stop in the same system. Data is hosted in the AWS EU region, and Fabrico and the company behind it hold ISO/IEC 27001, ISO/IEC 20000-1 and ISO 9001.
Book a Fabrico demoRelated tools: full troubleshooting directory · OEE calculator · downtime cost · MTBF / MTTR · glossary
Methods that cut recurring stops: the six big losses · root cause analysis · preventive vs predictive maintenance · TPM · SMED & changeover