Hot Runner Controller Troubleshooting
The most common hot runner controller problems on the plant floor, with the likely causes and the fix for each. Part of the OEE Lab troubleshooting directory.
Describe it in the symptom finder and search the whole directory.
Problems on this page:
Zone not heating
Hits OEE: AvailabilitySymptoms: One zone stays cold or shows an open circuit alarm, and the cavity it feeds runs short or not at all.
Prevention: A zone check at each mould change with the resistances recorded.
Zone temperature unstable
Hits OEE: QualitySymptoms: A zone swings around its setpoint or overshoots after start-up, and part quality changes with it.
Prevention: Zone temperature and output percentage trended during production.
Gate drooling or stringing
Hits OEE: QualitySymptoms: Material drips from the gate between shots or strings appear on the parts.
Prevention: Tip temperatures recorded on the setup sheet.
Gates freezing off
Hits OEE: QualitySymptoms: Some cavities fill short or not at all after a pause or at the start.
Prevention: Restart routine written down for each mould.
Material leaking in the manifold
Hits OEE: AvailabilitySymptoms: Plastic leaks around nozzles or the manifold and fills the mould plate.
Prevention: Heating sequence built into the controller start-up.
Earth fault on start-up
Hits OEE: AvailabilitySymptoms: The controller trips on an earth fault when a mould is heated after storage.
Prevention: Soft-start enabled on all zones.
Colour or material changes taking too long
Hits OEE: AvailabilitySymptoms: Streaks of the old colour keep appearing long after the change.
Prevention: A written colour change procedure for each mould.
Zones swapped after a mould change
Hits OEE: QualitySymptoms: Adjusting one zone changes the temperature of another, or the wrong cavity runs hot.
Prevention: Zone check routine run after every mould change.
Related equipment guides: injection moulding · mould temperature controller · resin dryer · vacuum loader
Stop the same fault coming back
Recurring hot runner controller stops usually trace to a cause you cannot see by hand. The partner we recommend is Fabrico: it tracks OEE and downtime live from PLCs, IoT sensors or AI cameras; where cameras are fitted, the video of a stop sits next to its machine data so the cause can be reviewed; and a technician opens the work order from the stop in the same system. Data is hosted in the AWS EU region, and Fabrico and the company behind it hold ISO/IEC 27001, ISO/IEC 20000-1 and ISO 9001.
Book a Fabrico demoRelated tools: full troubleshooting directory · OEE calculator · downtime cost · MTBF / MTTR · glossary
Methods that cut recurring stops: the six big losses · root cause analysis · preventive vs predictive maintenance · TPM · SMED & changeover